PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 1, 2013Journal of Cardiothoracic Surgery0 citationsOpen Access

Transapical aortic valve implantation in a patient with increased diameter of the aortic annulus and extensive calcification

ÁRÁlvaro Machado RöslerSBSimone BertaniJFJ Fraportti

Key Result

Transapical TAVI was performed successfully despite an aortic annulus diameter larger than the prosthesis limit, suggesting extensive calcification may aid in prosthesis anchoring.

Study Design

Type

Case Report (n=1)

Multicenter

No

Structured PICO

P
Population
A 66-year-old male with severe aortic stenosis, extensive calcification, and an aortic annulus diameter exceeding standard limits who underwent transapical TAVI.
I
Intervention
Transapical aortic valve implantation (TAVI) using an Inovare prosthesis.
O
Outcome
Procedural success and in-hospital postoperative course

TAVI can be successfully performed in patients with an aortic annulus diameter exceeding predefined limits if extensive calcification is present to anchor the prosthesis.

Abstract

TAVI is an option for patients with severe aortic stenosis and high surgical risk. The choice of prosthesis is based on anatomical measurements. We report the case of a patient who underwent TAVI with the average diameter of aortic annulus above the predefined limit. The patient is a 66y old male referred for evaluation of aortic stenosis, and presenting with fatigue, class III heart failure, hypertension, diabetes, 1st degree AV block, LBBB, previous stroke and moderate CKD. EuroSCORE I was 5.35% and EuroSCORE II was 1.98%. Echocardiography confirmed severe aortic stenosis, with an annulus 0.8 cm2, mean and peak systolic gradient 54 and 86 mmHg, and ejection fraction 59%. CT angiography showed a mean annulus diameter 28.4mm, sinotubular region 33.5mm, ascending aorta 41.1mm and volume of calcified region 892mm3. Given the low risk score, conventional surgery was indicated, but the patient rejected it and accepted only TAVI. Even the largest prosthesis available would require an aortic annulus diameter less than 26mm, versus 28,4mm from our patient. Despite this apparent mismatch and taking into consideration the extensive calcification and the patient's condition, the heart team, after exposing the risks to the patient and his family, indicated the transapical procedure. The procedure was performed successfully in February 2013 by transapical access, using a Inovare prosthesis (Braile Biomédica). Heart block required implant of a dual chamber pacemaker. Echocardiography on site showed normal prosthesis function with peak gradient 21mmHg, without evidence of leak or regurgitation. In-hospital postoperative course was uneventful; the patient was discharged asymptomatic after 13 days. TAVI procedure can be performed successfully even with the increased diameter of the aortic annulus, suggesting that the presence of extensive calcifications in the valve apparatus may have an impact on the selection of the prosthesis size.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Rösler et al. (2013) conducted a case report in Severe aortic stenosis (n=1). Transapical aortic valve implantation (TAVI) was evaluated on Procedural success and prosthesis function. Transapical TAVI was performed successfully despite an aortic annulus diameter larger than the prosthesis limit, suggesting extensive calcification may aid in prosthesis anchoring.

synapsesocial.com/papers/6a71b3bb78a11c550e0bb4c2https://doi.org/10.1186/1749-8090-8-s1-p179
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Bailout transcatheter aortic valve implantation for a bicuspid aortic valve with severe mixed aortic valve disease presenting in cardiogenic shock2024
  2. 2Transcatheter implantation of an aortic valve prosthesis in a female patient with severe bicuspid aortic stenosis2011 · 18 citations
  3. 3Transapical Transcatheter Aortic Valve Replacement Under 3-Dimensional Guidance to Treat Pure Aortic Regurgitation in Patients with a Large Aortic Annulus2024 · 1 citations
  4. 4Sizing the aortic annulus.2012 · 37 citations
  5. 5Transcatheter aortic valve implantation in large and extra-large aortic annuli: Contemporary evidence and performance of third-generation devices2025