PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 22, 2010Pharmacogenomics63 citations

VKORC1 , CYP2C9 and CYP4F2 Genetic-based Algorithm for Warfarin Dosing: An Italian Retrospective Study

View Full Paper
CZCarlo‐Federico ZambonVPVittorio PengoRPRoberto Padrini

Structured PICO

Does a novel pharmacogenetic algorithm accurately predict individual warfarin maintenance doses in Italian patients?

P
Population
371 Italian patients under stable warfarin therapy
I
Intervention
Pharmacogenetic algorithm for warfarin dosing incorporating VKORC1, CYP2C9 and CYP4F2 polymorphisms, body surface area, and age
C
Comparator
Three previously published pharmacogenetic algorithms
O
Outcome
Percentage of cases whose predicted mean weekly warfarin dose was within 20% of the actual maintenance dosesurrogate

A novel pharmacogenetic algorithm incorporating VKORC1, CYP2C9, and CYP4F2 genotypes accurately predicts warfarin maintenance doses, particularly for patients requiring low or high doses.

Limitations

  • Requires prospective clinical validation

Abstract

AIM: A total of 371 patients under stable warfarin therapy were retrospectively selected to develop a pharmacogenetic algorithm to identify the individual maintenance dose. MATERIALS & METHODS: The variables that were entered into the algorithm were: VKORC1, CYP2C9 and CYP4F2 polymorphisms, body surface area and age. RESULTS: The percentage of cases whose predicted mean weekly warfarin dose was within 20% of the actual maintenance dose was 51.8% considering patients overall, and were 36.2, 66.2 and 55.4%, respectively, taking into account patients requiring low (≤25 mg/week), intermediate (25-45 mg/week) and high (≥45 mg/week) doses. The algorithm could correctly assign 73.8 and 63.2% of patients to the low- and high-dose regimens, respectively. We developed and validated a pharmacogenetic algorithm in a series of Italian patients, we then tested, in the same series of italian patients, the formulas of three published algorithms. These three algorithms were developed and validated by their authors in a series of patients different from our own. The performance of our algorithm in our patients series was slightly higher than that achieved when using the three other algorithms in our patients series. CONCLUSION: The high predictive accuracy of low and high warfarin requirements of our algorithm warrants its application in prospective studies for clinical validation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zambon et al. (2010) studied this question.

synapsesocial.com/papers/6a72549984cc45bb7be01a34https://doi.org/10.2217/pgs.10.162
Ask AI
Helpful
Bookmark
Share
View Full Paper