November 27, 2021Annals of Intensive Care39 citationsOpen Access

Optimizing high-flow nasal cannula flow settings in adult hypoxemic patients based on peak inspiratory flow during tidal breathing

JLJie LiJSJ Brady ScottJFJames B. Fink

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Background Optimal flow settings during high-flow nasal cannula (HFNC) therapy are unknown. We investigated the optimal flow settings during HFNC therapy based on breathing pattern and tidal inspiratory flows in patients with acute hypoxemic respiratory failure (AHRF). Methods We conducted a prospective clinical study in adult hypoxemic patients treated by HFNC with a fraction of inspired oxygen (F I O 2 ) ≥ 0.4. Patient’s peak tidal inspiratory flow (PTIF) was measured and HFNC flows were set to match individual PTIF and then increased by 10 L/min every 5–10 min up to 60 L/min. F I O 2 was titrated to maintain pulse oximetry (SpO 2 ) of 90–97%. SpO 2 /F I O 2 , respiratory rate (RR), ROX index (SpO 2 /F I O 2 )/RR, and patient comfort were recorded after 5–10 min on each setting. We also conducted an in vitro study to explore the relationship between the HFNC flows and the tracheal F I O 2 , peak inspiratory and expiratory pressures. Results Forty-nine patients aged 58.0 (SD 14.1) years were enrolled. At enrollment, HFNC flow was set at 45 (38, 50) L/min, with an F I O 2 at 0.62 (0.16) to obtain an SpO 2 /F I O 2 of 160 (40). Mean PTIF was 34 (9) L/min. An increase in HFNC flows up to two times of the individual patient’s PTIF, incrementally improved oxygenation but the ROX index plateaued with HFNC flows of 1.34–1.67 times the individual PTIF. In the in vitro study, when the HFNC flow was set higher than PTIF, tracheal peak inspiratory and expiratory pressures increased as HFNC flow increased but the F I O 2 did not change. Conclusion Mean PTIF values in most patients with AHRF were between 30 and 40 L/min. We observed improvement in oxygenation with HFNC flows set above patient PTIF. Thus, a pragmatic approach to set optimal flows in patients with AHRF would be to initiate HFNC flow at 40 L/min and titrate the flow based on improvement in ROX index and patient tolerance. Trial registration : ClinicalTrials.gov (NCT03738345). Registered on November 13th, 2018. https://clinicaltrials.gov/ct2/show/NCT03738345?term=NCT03738345&draw=2&rank=1

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Li et al. (2021) studied this question.

synapsesocial.com/papers/6a79324f5968508e56f36775https://doi.org/10.1186/s13613-021-00949-8
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Post-extubation oxygenation strategies in acute respiratory failure: a systematic review and network meta-analysis2021 · 66 citations
  2. 2Comparison of the Sp o 2 /F io 2 Ratio and the Pa o 2 /F io 2 Ratio in Patients With Acute Lung Injury or ARDS2007 · 876 citations
  3. 3The Effects of Flow on Airway Pressure During Nasal High-Flow Oxygen Therapy2011 · 399 citations
  4. 4Increasing support by nasal high flow acutely modifies the ROX index in hypoxemic patients: A physiologic study2019 · 54 citations
  5. 5Positive End-Expiratory Pressure Effect of 3 High-Flow Nasal Cannula Devices2017 · 55 citations