September 17, 2015Journal of Visualized Experiments33 citations

Cardiac Pressure-Volume Loop Analysis Using Conductance Catheters in Mice

DADennis AbrahamLMLan Mao

Key Result

Cardiac pressure-volume loop analysis using conductance catheters allows for the assessment of ventricular systolic and diastolic function in mice.

Structured PICO

P
Population
Mice (small mammals, including genetic mutant models or drug treatment studies)
I
Intervention
Cardiac pressure-volume loop analysis using conductance catheters
O
Outcome
Measures of ventricular systolic and diastolic function (contractility and compliance)surrogate

This review provides a methodological guide for performing accurate and precise cardiac pressure-volume loop analysis using conductance catheters in mice.

Abstract

Cardiac pressure-volume loop analysis is the "gold-standard" in the assessment of load-dependent and load-independent measures of ventricular systolic and diastolic function. Measures of ventricular contractility and compliance are obtained through examination of cardiac response to changes in afterload and preload. These techniques were originally developed nearly three decades ago to measure cardiac function in large mammals and humans. The application of these analyses to small mammals, such as mice, has been accomplished through the optimization of microsurgical techniques and creation of conductance catheters. Conductance catheters allow for estimation of the blood pool by exploiting the relationship between electrical conductance and volume. When properly performed, these techniques allow for testing of cardiac function in genetic mutant mouse models or in drug treatment studies. The accuracy and precision of these studies are dependent on careful attention to the calibration of instruments, systematic conduct of hemodynamic measurements and data analyses. We will review the methods of conducting pressure-volume loop experiments using a conductance catheter in mice.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Abraham et al. (2015) conducted a review in Cardiac function assessment in mice. Cardiac pressure-volume loop analysis using conductance catheters was evaluated. Cardiac pressure-volume loop analysis using conductance catheters allows for the assessment of ventricular systolic and diastolic function in mice.

synapsesocial.com/papers/6a7c979bb7ca9b673b7ccd26https://doi.org/10.3791/52942
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Validation of Conductance Catheter System for Quantification of Murine Pressure-Volume Loops2001 · 55 citations
  2. 2Biventricular Assessment of Cardiac Function and Pressure-Volume Loops by Closed-Chest Catheterization in Mice2020 · 11 citations
  3. 3Cardiac Catheterization in Mice to Measure the Pressure Volume Relationship: Investigating the Bowditch Effect2015 · 10 citations
  4. 4In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry1998 · 254 citations
  5. 5Validation of a mouse conductance system to determine LV volume: comparison to echocardiography and crystals2000 · 88 citations