February 26, 2015IEEE Transactions on Smart Grid66 citations

Preventing Occupancy Detection From Smart Meters

View Full Paper
CDChen DongSKSandeep KalraDIDavid Irwin

Key Points

Key points are not available for this paper at this time.

Abstract

Utilities are rapidly deploying smart meters that measure electricity usage in real-time. Unfortunately, smart meters indirectly leak sensitive information about a home's occupancy, which is easy to detect because it highly correlates with simple statistical metrics, such as power's mean, variance, and range. To prevent occupancy detection, we propose using the thermal energy storage of electric water heaters already present in many homes. In essence, our approach, which we call combined heat and privacy (CHPr), modulates a water heater's power usage to make it look like someone is always home. We design a CHPr-enabled water heater that regulates its energy usage to thwart a variety of occupancy detection attacks without violating its objective-to provide hot water on demand-and evaluate it in simulation using real data. Our results show that a standard 50-gal CHPr-enabled water heater prevents a wide range of state-of-the-art occupancy detection attacks.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dong et al. (2015) studied this question.

synapsesocial.com/papers/6a7ca5ccec6509d062ba5ce8https://doi.org/10.1109/tsg.2015.2402224