PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 14, 2017Journal of Veterinary Internal Medicine19 citationsOpen Access

Measurement Variation and Repeatability of Echocardiographic Variables Used to Estimate Pulmonary Artery Pressure in Dogs

View Full Paper
JAJonathan A. AbbottJGJessica Gentile-Solomon

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Background Pulmonary hypertension (PH) is an important clinical entity in dogs. Pulmonary hypertension is generally identified based on echocardiographic findings, but measurement variation of the variables most often used in this context has not been reported. Objective To define measurement variation of echocardiographic variables that are used to estimate pulmonary artery pressure. Animals Four dogs with subclinical tricuspid valve regurgitation were selected from a hospital population. Methods Prospective descriptive study - dogs were subject to repeated echocardiographic examination by 2 operators. Each dog was echocardiographically examined 12 times, once by each operator during mornings and afternoons of 3 nonconsecutive days. Measurement variation was defined by coefficients of variation and by mean square errors (MSE) from ANOVA models. Repeatability coefficients (RC) were calculated from MSE. Results Of 50 within-day, between-day, and interoperator coefficients of variation (CVs), 37 were less than 10% and 46 were less than 15%. The range of peak velocity of tricuspid valve regurgitation (VTR) VTR was 1.87–3.34 m/s. Analysis of variance revealed a significant effect (P 0.05) of operator for 7 of 10 measurements. Within-operator/between-day/within-subject and between-operator/between-day/within-subject RCs of VTR were, respectively, 0.3 and 0.6 m/s. Conclusions and Clinical Importance With regard to repeatability, VTR is superior to other methods used for echocardiographic estimation of systolic pulmonary artery pressure. When TR is absent, the acceleration time of pulmonary ejection and the acceleration-to-ejection time ratio are alternative measures. A change in VTR exceeding 0.3 m/s might be outside the range of expected within-operator variation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Abbott et al. (2017) studied this question.

synapsesocial.com/papers/6a7ccf5aa2d66b66445bc497https://doi.org/10.1111/jvim.14846
Ask AI
Helpful
Bookmark
Share
View Full Paper