The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial

TBTadej BattelinoICIgnacio CongetBOBirthe Susanne Olsen

Key Points

Key points are not available for this paper at this time.

Abstract

AIMS/HYPOTHESIS: The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes. METHODS: Children and adults (n = 153) on CSII with HbA(1c) 7.5-9.5% (58.5-80.3 mmol/mol) were randomised to (CGM) a Sensor On or Sensor Off arm for 6 months. After 4 months' washout, participants crossed over to the other arm for 6 months. Paediatric and adult participants were separately electronically randomised through the case report form according to a predefined randomisation sequence in eight secondary and tertiary centres. The primary outcome was the difference in HbA(1c) levels between arms after 6 months. RESULTS: Seventy-seven participants were randomised to the On/Off sequence and 76 to the Off/On sequence; all were included in the primary analysis. The mean difference in HbA(1c) was -0.43% (-4.74 mmol/mol) in favour of the Sensor On arm (8.04% 64.34 mmol/mol vs 8.47% 69.08 mmol/mol; 95% CI -0.32%, -0.55% -3.50, -6.01 mmol/mol; p < 0.001). Following cessation of glucose sensing, HbA(1c) reverted to baseline levels. Less time was spent with sensor glucose <3.9 mmol/l during the Sensor On arm than in the Sensor Off arm (19 vs 31 min/day; p = 0.009). The mean number of daily boluses increased in the Sensor On arm (6.8 ± 2.5 vs 5.8 ± 1.9, p < 0.0001), together with the frequency of use of the temporary basal rate (0.75 ± 1.11 vs 0.26 ± 0.47, p < 0.0001) and manual insulin suspend (0.91 ± 1.25 vs 0.70 ± 0.75, p < 0.018) functions. Four vs two events of severe hypoglycaemia occurred in the Sensor On and Sensor Off arm, respectively (p = 0.40). CONCLUSIONS/INTERPRETATION: Continuous glucose monitoring was associated with decreased HbA(1c) levels and time spent in hypoglycaemia in individuals with type 1 diabetes using CSII. More frequent self-adjustments of insulin therapy may have contributed to these effects.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Battelino et al. (2012) studied this question.

synapsesocial.com/papers/6a7d167945db7d096f6e468ehttps://doi.org/10.1007/s00125-012-2708-9
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes2010 · 898 citations
  2. 2Assessment of Patient-Led or Physician-Driven Continuous Glucose Monitoring in Patients With Poorly Controlled Type 1 Diabetes Using Basal-Bolus Insulin Regimens2012 · 93 citations
  3. 3Sensor-augmented pump therapy lowers HbA1c in suboptimally controlled Type 1 diabetes; a randomized controlled trial2011 · 167 citations
  4. 4Improved Glycemic Control in Poorly Controlled Patients with Type 1 Diabetes Using Real-Time Continuous Glucose Monitoring2006 · 545 citations
  5. 5Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study2008 · 297 citations