July 15, 1985Journal of Applied Physics78 citations

Evaluation of ionic mobility and transference number in a polymeric solid electrolyte by isothermal transient ionic current method

View Full Paper
MWMasayoshi WatanabeMRMasahiro RikukawaKSKohei Sanui

Key Points

Key points are not available for this paper at this time.

Abstract

We proposed a new method for evaluating mobilities of both Li+ and SCN− ions in a polymeric solid electrolyte formed by poly (ethylene succinate) and LiSCN. The method is based on the isothermal transient ionic current (ITIC) technique by using an ion-blocking platinum electrode and an ion-reversible lithium electrode. The differences of the ITIC profiles, depending on the kind of the electrodes, provided both mobilities of Li+ and SCN− ions, and their assignment. The mobilities of Li+ and SCN− ions at 90 °C were 1.3–4.2×10−6 cm2 V−1 s−1 and 5.3–10.7×10−8 cm2 V−1 s−1, respectively. The transference number of Li+ ions was 0.92–0.99.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Watanabe et al. (1985) studied this question.

synapsesocial.com/papers/6a7d3249d2282bebd3aa0b19https://doi.org/10.1063/1.336191