January 1, 2004Journal of Environmental Monitoring36 citations

Determination of CH 4 , CO 2 and N 2 O in air samples and soil atmosphere by gas chromatography mass spectrometry, GC-MS

View Full Paper
DEDag EkebergGOGunnar OgnerMFMonica Fongen

Key Points

Key points are not available for this paper at this time.

Abstract

A method for determination of the climate gases CH4, CO2 and N2O in air samples and soil atmosphere was developed using GC-MS. The method uses straightforward gas chromatography (separation of the gases) with a mass spectrometric detector in single ion mode (specific determination). The gases were determined with high sensitivity and high sample throughput (18 samples h(-1)). The LOD (3sigma) for the gases were 0.10 micro L L(-1) for CH4, 20 microL L(-1) for CO2 and 0.02 microL L(-1) for N2O. The linear range (R2 = 0.999) was up to 500 microL L(-1) for CH4, 4000 microL L(-1) for CO2 and 80 microL L(-1) for N2O. The samples were collected in 10 mL vials and a 5 microL aliquot was injected on column. The method was tested against certified gas references, the analytical data gave an accuracy within +/-5% and a precision of +/-3%. The presence of < or = 10% by volume of C2H2 (often used experimentally to prevent N2 formation from N2O) did not interfere with detection for the targeted trace gases.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ekeberg et al. (2004) studied this question.

synapsesocial.com/papers/6a7d4063e9cd826fb346d0b2https://doi.org/10.1039/b401315h