PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 16, 2013Acta Radiologica18 citations

Biexponential analysis of diffusion-weighted imaging: comparison of three different calculation methods in transplanted kidneys

View Full Paper
PHPhilipp HeuschHWHans‐Jörg WittsackGPGael Pentang

Key Points

Key points are not available for this paper at this time.

Abstract

BACKGROUND: Biexponential analysis has been used increasingly to obtain contributions of both diffusion and microperfusion to the signal decay in diffusion-weighted imaging DWI of different parts of the body. PURPOSE: To compare biexponential diffusion parameters of transplanted kidneys obtained with three different calculation methods. MATERIAL AND METHODS: DWI was acquired in 15 renal allograft recipients (eight men, seven women; mean age, 52.4 ± 14.3 years) using a paracoronal EPI sequence with 16 b-values (b = 0-750 s/mm(2)) and six averages at 1.5T. No respiratory gating was used. Three different calculation methods were used for the calculation of biexponential diffusion parameters: Fp, ADCP, and ADCD were calculated without fixing any parameter a priori (calculation method 1); ADCP was fixed to 12.0 µm(2)/ms, whereas Fp and ADCD were calculated using the biexponential model (calculation method 2); multistep approach with monoexponential fitting of the high b-value portion (b ≥ 250 s/mm(2)) for determination of ADCD and assessment of the low b intercept for determination of Fp (calculation method 3). For quantitative analysis, ROI measurements were performed on the according parameter maps. RESULTS: Mean ADCD values of the renal cortex using calculation method 1 were significantly lower than using calculation methods 2 and 3 (P < 0.001). There was a significant correlation between calculation methods 1 and 2 (r = 0.69 (P < 0.005) and calculation methods 1 and 3 (r = 0.59; P < 0.05) as well as calculation methods 2 and 3 (r = 0.98; P < 0.001). Mean Fp values of the renal cortex were higher with calculation method 1 than with calculation methods 2 and 3 (P < 0.001). For Fp, only the correlation between calculation methods 2 and 3 was significant (r = 0.98; P < 0.001). CONCLUSION: Biexponential diffusion parameters differ significantly depending on the calculation methods used for their calculation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Heusch et al. (2013) studied this question.

synapsesocial.com/papers/6a7d85d7286d888403cda075https://doi.org/10.1177/0284185113491090
Ask AI
Helpful
Bookmark
Share
View Full Paper