PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 1980Circulation63 citationsOpen Access

Accuracy and reproducibility of new M-mode echocardiographic recommendations for measuring left ventricular dimensions.

View Full Paper
MCMichael H. CrawfordDGDaniel GrantRORobert A. O’Rourke

Structured PICO

Does the proposed ASE method improve the accuracy and reproducibility of measuring left ventricular dimensions compared to current techniques in normal subjects and patients without CAD?

P
Population
74 subjects (50 normal subjects and 24 patients without coronary artery disease who had symmetrically contracting ventricles on cineangiography)
I
Intervention
Proposed American Society of Echocardiography (ASE) method for measuring left ventricular dimensions on M-mode echocardiograms
C
Comparator
Current technique and cineangiography
O
Outcome
Accuracy and reproducibility of end-diastolic (Dd) and end-systolic (Ds) dimensionssurrogate

The proposed ASE method for measuring left ventricular dimensions overestimates volumes compared to angiography and is not clearly superior to existing techniques.

Abstract

In order to assess the accuracy and reproducibility of the proposed American Society of Echocardiography (ASE) method for measuring left ventricular dimensions on M-mode echocardiograms, we measured the end-diastolic (Dd) and end-systolic (Ds) dimensions by the ASE method and our current technique in 50 normal subjects and 24 patients without coronary artery disease who had symmetrically contracting ventricles on cineangiography. Dd and Ds were significantly greater by the proposed ASE method than by our current technique (p less than 0.001), but the correlation between the two was good (r = 0.93 and 0.83, respectively). In 10 of the normal subjects, the interobserver variability of both methods was excellent. In the 24 patients, the proposed method consistently overestimated the angiographic left ventricular volumes compared with our current technique and occasionally the discrepancies were quite large. Therefore, the proposed ASE method for measuring left ventricular dimensions is not clearly superior to other currently available techniques.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Crawford et al. (1980) studied this question.

synapsesocial.com/papers/6a7f06d08ba53d470169a736https://doi.org/10.1161/01.cir.61.1.137
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Determination of Left Ventricular Volumes by Ultrasound1971 · 288 citations
  2. 2Evaluation of Left Ventricular Function by Echocardiography1972 · 249 citations
  3. 3Left Ventricular Volumes and Ejection Fraction by Echocardiography1971 · 651 citations
  4. 4Measurement of Left Ventricular Volumes in Man by Single-plane Cineangiocardiography1969 · 260 citations
  5. 5Direct Correlation of External Systolic Time Intervals with Internal Indices of Left Ventricular Function in Man1971 · 193 citations