December 1, 1997Journal of Hypertension30 citationsOpen Access

Reproducibility of twenty-four-hour finger arterial blood pressure, variability and systemic hemodynamics

AVAlbertus J. VoogelGMGert A. van Montfrans

Structured PICO

Is 24-hour non-invasive continuous monitoring of finger arterial blood pressure by Portapres reproducible in hypertensive and normotensive subjects?

P
Population
18 subjects (10 patients with untreated essential hypertension and 8 normotensive subjects)
I
Intervention
24-hour non-invasive continuous monitoring of finger arterial blood pressure by Portapres on two occasions with 1-4 weeks in-between
O
Outcome
Reproducibility (accuracy and precision) of prolonged blood pressure recordings and stroke volumesurrogate

The Portapres device provides reliable and reproducible 24-hour non-invasive continuous blood pressure monitoring, serving as a viable substitute for intra-arterial recording.

Abstract

OBJECTIVE: At present, non-invasive continuous monitoring of finger arterial blood pressure by the volume-clamp technique is considered the best approach to obtain reliable assessments of beat-to-beat blood pressure. However, data on the reproducibility (accuracy and precision) of prolonged recordings and of the hemodynamics derived from wave-form analysis are not available. DESIGN: Ten patients with untreated essential hypertension and eight normotensive subjects were monitored by Portapres over 24 h in the hospital on two occasions with 1-4 weeks in-between. Physical and mental activities were standardized as far as possible to minimize intra- and intersubject biological variability. Stroke volume was obtained by the Modelflow method. Differences between the two recordings were computed separately for the day (0700 to 2300 h) and the night (2300 to 0700 h) and for all hours. Differences in stroke volume were calculated as percentage change from the first recording. RESULTS: Accuracy was good in both groups and bias was close to zero. Precision was also remarkable in the daytime, and at least as good as values reported in studies that used the standard intra-arterial recording. The SD of the differences in systolic and diastolic pressure in the hypertensives in the daytime were 6.6 and 4.7 mmHg, respectively. At night, precision was less good, possibly because of the 30 min finger-cuff switching: 12.5 and 6.5 mmHg for systolic and diastolic pressure, respectively. The average stroke volume did not change more than 8% at most between the first and the second recordings. CONCLUSION: These results indicate that the Finapres and Portapres devices are a reliable substitute for intra-arterial recording, and are most useful instruments for the study of blood pressure regulation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Voogel et al. (1997) studied this question.

synapsesocial.com/papers/6a817206462be2b31d22cdaahttps://doi.org/10.1097/00004872-199715120-00086
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring1992 · 72 citations
  2. 2Reproducibility of non-invasive and intra-arterial blood pressure monitoring: implications for studies on antihypertensive treatment1991 · 159 citations
  3. 3A test of reproducibility of blood pressure and heart rate variability using a controlled ambulatory procedure1993 · 36 citations
  4. 4Variability of Indirect Methods Used to Determine Blood Pressure1992 · 43 citations
  5. 5Prognostic value of 24-hour blood pressure variability1993 · 660 citations