July 1, 2005Journal of Veterinary Internal Medicine29 citations

Effect of Body Position on Feline Electrocardiographic Recordings

View Full Paper
AHAndrea HarveyMFM. FaenaPDP. G. G. Darke

Structured PICO

Does body position (sternal or left lateral vs right lateral recumbency) alter electrocardiographic parameters in cats?

P
Population
41 cats presenting in sinus rhythm referred to the Feline Unit of the University of Bristol (38 for potential cardiac disease investigation, 3 for preanesthetic screen).
I
Intervention
Standard 6-lead ECGs recorded in sternal (ST) and left lateral (LL) recumbency
C
Comparator
Standard 6-lead ECGs recorded in right lateral (RL) recumbency
O
Outcome
Amplitude and duration of P waves and QRS complexes, duration of PQ and QT intervals, and mean electrical axis (MEA)surrogate

Sternal and left lateral recumbencies significantly alter R wave amplitude and mean electrical axis in feline ECGs compared to standard right lateral recumbency, and should not be used for comparison with standard references.

Abstract

The aim of this study was to determine whether changes in body position alter feline electrocardiographic parameters. Forty-seven cats referred to the Feline Unit of the University of Bristol had electrocardiograms (ECGs) recorded. Only cats presenting in sinus rhythm were included in the study (n = 41). ECGs were recorded either as part of the investigation for potential cardiac disease (n = 38) or as a preanesthetic screen (n = 3). Standard 6-lead ECGs (leads I, II, III, aVR, aVL, and aVF) were recorded in 3 different recumbent positions in the 41 cats. Recordings were 1st made in right lateral (RL) recumbency, followed by sternal (ST) and then left lateral (LL) recumbency. Measurements were taken of the amplitude and duration of P waves and QRS complexes and duration of PQ and QT intervals from lead II was taken in the 3 different positions. Mean electrical axis (MEA) also was calculated. Repeated measures analysis of variance was performed and identified a significant difference in R wave amplitudes (P = .009) and MEA (P = .037) among the 3 different body positions. Two-tailed paired t-tests demonstrated that the R wave amplitude differed significantly both in ST (P = .025) and LL recumbency (P = .009). The mean R wave amplitude was reduced in both ST and LL recumbency when compared with RL recumbency. The MEA only was significantly different in LL recumbency (P = .037). ST and LL recumbencies should not be used for recording ECGs in cats if amplitudes and MEA are to be compared with standard references.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Harvey et al. (2005) studied this question.

synapsesocial.com/papers/6a81e7f9bbb70d3ba94cd7aehttps://doi.org/10.1111/j.1939-1676.2005.tb02723.x
Ask AI
Helpful
Bookmark
Share
View Full Paper