A comparison of transoesophageal echocardiographic Doppler across the aortic valve and the thermodilution technique for estimating cardiac output

View Full Paper
JPJan PoelaertCSC. G. SchmidtHAHugo Van Aken

Structured PICO

Does transoesophageal echocardiographic Doppler across the aortic valve accurately estimate cardiac output compared to the thermodilution technique in coronary artery bypass patients?

P
Population
45 coronary artery bypass patients
I
Intervention
Transoesophageal echocardiographic Doppler across the aortic valve (pulsed- and continuous-wave Doppler in transverse and longitudinal planes)
C
Comparator
Thermodilution technique
O
Outcome
Cardiac output estimation (correlation between Doppler techniques and thermodilution)surrogate

Transoesophageal pulsed-wave Doppler echocardiography across the aortic valve provides adequate estimations of cardiac output that correlate well with the thermodilution clinical standard.

Abstract

This study was undertaken in order to elucidate the differences between various planes of measurement and Doppler techniques (pulsed- vs. continuous-wave Doppler) across the aortic valve to estimate cardiac output. In 45 coronary artery bypass patients, cardiac output was measured each time using four different Doppler techniques (transverse and longitudinal plane, pulsed- and continuous-wave Doppler) and compared with the thermodilution technique. Measurements were performed after induction of anaesthesia and shortly after arrival in the intensive care unit. Optimal imaging was obtained in 91% of the patients, in whom a total of 82 measurements of cardiac output were performed. The respective mean (SD) areas of the aortic valve were 3.77 (0.71) cm2 in the transverse plane and 3.86 (0.89) cm2 in the longitudinal plane. A correlation of 0.87 was found between pulsed-wave Doppler cardiac output and the thermodilution technique in either transverse or longitudinal plane. Correlation coefficients of 0.82 and 0.84 were found between thermodilution cardiac output and transverse and longitudinal continuous-wave Doppler cardiac output, respectively. Although thermodilution cardiac output is a widely accepted clinical standard, transoesophageal Doppler echocardiography across the aortic valve offers adequate estimations of cardiac output. In particular, pulsed-wave Doppler cardiac output in both the transverse and longitudinal plane provides useful data.