December 12, 1981BMJ33 citationsOpen Access

An evaluation of flexible fibreoptic sigmoidoscopy.

KVK D VellacottJHJ D Hardcastle

Key Points

Key points are not available for this paper at this time.

Abstract

Results of 350 flexible fibreoptic sigmoidoscopy examinations showed a diagnostic yield of 30% compared with 6.5% by rigid sigmoidoscopy of the same patients. The mean time for the examinations was eight minutes, a distance of over 50 cm being visualised in 65% of the patients. Preparation of the bowel with a single phosphate enema was adequate in 95% of the patients. As an outpatient investigation for clinicians fibreoptic sigmoidoscopy is a safe, quick, and useful addition to rigid sigmoidoscopy and should result in a decrease in the number of barium enema examinations required.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Vellacott et al. (1981) studied this question.

synapsesocial.com/papers/6a8383cccdfa22bd6cd10057https://doi.org/10.1136/bmj.283.6306.1583