PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 1, 2008Journal of Nuclear Medicine85 citationsOpen Access

Radiopharmaceuticals for Nuclear Cardiology: Radiation Dosimetry, Uncertainties, and Risk

MSMichael G. Stabin

Key Points

Key points are not available for this paper at this time.

Abstract

UNLABELLED: The technical basis for the dose estimates for several radiopharmaceuticals used in nuclear cardiology is reviewed, and cases in which uncertainty has been encountered in the dosimetry of an agent are discussed. Also discussed is the issue of uncertainties in radiation dose estimates and how to compare the relative risks of studies. METHODS: Radiation dose estimates (organ absorbed doses and effective doses) from different literature sources were directly compared. Typical values for administered activity per study were used to compare doses that are to be expected in clinical applications. RESULTS: The effective doses for all agents varied from 2 to 15 mSv per study, with the lowest values being seen for (13)N-NH(3) and (15)O-H(2)O studies and the highest values being seen for (201)Tl-chloride studies. The effective doses for (99m)Tc- and (201)Tl-labeled agents differed by about a factor of 2, a factor that is comparable to the uncertainty in individual values. This uncertainty results from the application of standard anthropomorphic and biokinetic models, presumably representative of the exposed population, to individual patients. CONCLUSION: Considerations such as diagnostic accuracy, ease of use, image quality, and patient comfort and convenience should generally dictate the choice of a radiopharmaceutical, with radiation dose being only a secondary or even tertiary consideration. Counseling of nuclear medicine patients who may be concerned about exposure should include a reasonable estimate of the median dose for the type of examination and administered activity of the radiopharmaceutical; in addition, it should be explained that the theoretic risks of the procedure are orders of magnitude lower than the actual benefits of the examination. Providing numeric estimates of risks from studies to individual patients is inappropriate, given the uncertainties in the dose estimates and the limited predictive power of current dose-risk models in the low-dose (i.e., diagnostic) range.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Michael G. Stabin (2008) studied this question.

synapsesocial.com/papers/6a865557ca7952c44d5ae6c8https://doi.org/10.2967/jnumed.108.052241
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Fifth international radiopharmaceutical dosimetry symposium1992 · 37 citations
  2. 2Testicular-scrotal content of 201Tl and 67Ga after intravenous administration1981 · 10 citations
  3. 3Technetium-99m-1,2-bis[bis(2-ethoxyethyl) phosphino]ethane: human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent.1993 · 325 citations
  4. 4Thallium-201 for medical use. Part 3: Human distribution and physical imaging properties.1977 · 159 citations
  5. 5The dynamics of ammonia metabolism in man. Effects of liver disease and hyperammonemia.1979 · 410 citations