PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 14, 2001Haemophilia63 citations

Laboratory diagnosis of von Willebrand disorder (vWD) and monitoring of DDAVP therapy: efficacy of the PFA‐100® and vWF:CBA as combined diagnostic strategies

View Full Paper
EFEmmanuel J. FavaloroGKGeoffrey KershawMBMelinda Bukuya

Key Points

Key points are not available for this paper at this time.

Abstract

We have coevaluated a combination of test processes for diagnosing von Willebrand disease (vWD) and monitoring deamino-delta-D-arginine vasopressin (DDAVP) therapy. Using normal controls (n = 23), closure time (CT) ranges measured by PFA-100(R) were (mean +/- 2SD): (i) collagen/ADP cartridge (C/ADP): 67-127 s (ii) collagen/epinephrine (C/Epi): 94-162 s. From a panel of 125 patients undergoing evaluation for clinical haemostatic defects, 29/30 samples from patients with vWD 17/18 type 1, 1/1 type 3, 3/3 type 2A, 7/7 type 2B and 1/1 pseudo-vWD gave prolonged CTs using C/Epi. The C/ADP was less sensitive, being normal in 7/18 of the type 1 vWD individuals, with higher sensitivity to more severe vWD. Individuals with haemophilia (six factor VIII-deficient, one factor XI-deficient) gave normal CTs, while those with clinical thrombocytopenia (n=13) gave normal or prolonged CTs, somewhat dependent on platelet count. The PFA-100 was also evaluated as a part of the laboratory monitoring procedure in patients with either vWD or haemophilia undergoing a DDAVP trial as a therapeutic management process. For vWD, correction of an initially prolonged CT by DDAVP, accompanied by normalization of von Willebrand factor (vWF) measurable by von Willebrand factor antigen, vWF collagen binding activity and vWF ristocetin cofactor assays (vWF:Ag, vWF:CBA and vWF:RCof), was achieved in type 1 vWD (n=5). In an individual with type 2A vWD, DDAVP normalized vWF:Ag and vWF:RCof, but had no apparent effect on the baseline maximally prolonged CT. In an individual with type 2B vWD, factor VIII/vWF concentrate also normalized vWF:Ag and vWF:RCof, but similarly had no apparent effect on the baseline maximally prolonged CT. vWF:CBA did not normalize for either of these individuals, potentially suggesting that normalization of vWF:CBA might be required for normalization of CT. This concept is supported by correlation analysis undertaken between CT and various vWF parameters. Among these, vWF:CBA held the strongest relationship in our data set, which showed an inverse progressive rise in CT for falling vWF:CBA. Based on these results, we would conclude that the PFA-100 is highly sensitive to the presence of vWD, and may thus provide a valuable screening test for vWD. Furthermore, the combined utility of the PFA-100 and vWF:CBA as markers of DDAVP responsiveness may prove to be simple, quick but powerful, predictors for its clinical efficacy.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Favaloro et al. (2001) studied this question.

synapsesocial.com/papers/6a86dbec540b033b21bef6dbhttps://doi.org/10.1046/j.1365-2516.2001.00487.x
Ask AI
Helpful
Bookmark
Share
View Full Paper