PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 22, 2005Medical Physics36 citations

Helical tomotherapy radiation leakage and shielding considerations

View Full Paper
JBJohn BalogDLD LucasCDCleber N. deSouza

Key Points

Key points are not available for this paper at this time.

Abstract

Leakage radiation and room shielding considerations increase significantly for intensity-modulated radiation therapy (IMRT) treatments due to the increased beam-on time to deliver modulated fields. Tomotherapy, with its slice by slice approach to IMRT, further exacerbates this increase. Accordingly, additional shielding is used in tomotherapy machines to reduce unwanted radiation. The competing effects of the high modulation and the enhanced shielding were studied. The overall room leakage radiation levels are presented for the continuous gantry rotations, which are always used during treatments. The measured leakage at 4 m from the isocenter is less than 3 x 10(-4) relative to calibration output. Primary radiation exposure levels were investigated as well. The effect of forward-directed leakage through the beam-collimation system was studied, as this is the leakage dose the patient would receive in the course of a treatment. A 12-min treatment was calculated to produce only 1% patient leakage dose to the periphery region. Longer treatment times might yield less patient dose if the field width selected is correspondingly narrower. A method for estimating the worst-case leakage dose a patient would receive is presented.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Balog et al. (2005) studied this question.

synapsesocial.com/papers/6a8ad28aeada60f85de3a4c4https://doi.org/10.1118/1.1861521
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Shielding considerations for tomotherapy2000 · 17 citations
  2. 2Optimization of helical tomotherapy treatment plans for prostate cancer2003 · 60 citations
  3. 3Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapy1993 · 1,074 citations
  4. 4NCRP Report No. 116, Limitation of Exposure to Ionizing Radiation: National Council on Radiation Protection, Bethesda, MD, 88 pages, $22.501994 · 183 citations
  5. 5Concurrent chemoradiation using paclitaxel and carboplatin in locally advanced non-small cell lung cancer.1999 · 265 citations