June 1, 2005American Journal of Roentgenology123 citationsOpen Access

Clinical Experience with MRI-Guided Vacuum-Assisted Breast Biopsy

CLConstance D. LehmanEDElizabeth R. DePeriSPSue Peacock

Key Points

Key points are not available for this paper at this time.

Abstract

OBJECTIVE: The objective of our study was to evaluate a new commercially available method of MRI-guided vacuum-assisted breast biopsy using an open coil and a closed 1.5-T scanner. MATERIALS AND METHODS: Consecutive MRI-guided vacuum-assisted breast biopsies of 38 lesions in 28 women performed between May and September 2003 at two practice sites in the United States were retrospectively reviewed. Lesion characteristics including size, morphology, and enhancement were recorded. Times to perform each procedure, defined as the time from the start of the first localizing scan to the final scan after biopsy, were recorded. Histologic results for all lesions were obtained, and surgical, imaging, or clinical follow-up was performed. RESULTS: Enhancing masses and foci ranged from 2.5 to 19 mm. Nonmasslike enhancements ranged from 6 to 70 mm. All 38 biopsies (100%) were technically successful, and no complications were associated with any of the biopsy procedures. The average time to perform the 19 single-site MRI-guided procedures was 38 min (range, 23-57 min). The 11 multiple-site biopsies performed in a single breast averaged 59 min (range, 51-68 min), and eight bilateral biopsies averaged 64 min (range, 46-80 min). Histologic results from vacuum-assisted breast biopsy revealed malignancy in 14 lesions (37%), atypical ductal hyperplasia in two lesions (5%), and benign findings in 22 lesions (58%). One of two lesions with atypical ductal hyperplasia was upgraded to ductal carcinoma in situ after surgery, for an overall cancer yield of 40% (15/38). CONCLUSION: This new method of MRI-guided vacuum-assisted breast biopsy is a safe, effective, and time-efficient means of MRI-guided tissue sampling.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lehman et al. (2005) studied this question.

synapsesocial.com/papers/6a8d3ff80b453ccb7788e020https://doi.org/10.2214/ajr.184.6.01841782
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1MRI-Guided Breast Biopsy: Clinical Experience with 14-Gauge Stainless Steel Core Biopsy Needle2004 · 57 citations
  2. 2MR imaging-guided localization and biopsy of breast lesions: initial experience.1994 · 195 citations
  3. 3MRI: An Image of the Future2006 · 1 citations
  4. 4Interventional breast MR imaging: clinical use of a stereotactic localization and biopsy device.1997 · 186 citations
  5. 5MR-guided Vacuum-assisted Breast Biopsy: Accuracy of Targeting and Success in Sampling in a Phantom Model2004 · 29 citations