April 1, 1992Journal of Turbomachinery25 citations

Two-Dimensional Flow Analysis of a Laboratory Centrifugal Pump

View Full Paper
SMS. M. MinerRFRonald D. FlackPAP. E. Allaire

Key Points

  • To model the two-dimensional velocity field and natural impeller-volute interaction in a laboratory centrifugal pump across multiple operating conditions using potential flow theory.
  • Simulated the impeller and volute simultaneously using finite element techniques across ten distinct angular impeller orientations.
  • Validated velocity profiles, stagnation point positions, and slip factors against experimental laser velocimeter data obtained from the same pump.
  • Circumferential velocity asymmetries reached differences of 0.12 m/s for radial and 0.38 m/s for tangential components at the impeller exit at design flow, representing roughly 25% of average velocity magnitudes.
  • Slip values ranged from 0.96 at the inlet to 0.71 at the exit at design flow, with the tongue stagnation point migrating from the discharge side to the impeller side as flow increased.
  • Computational simulations agreed with laser velocimeter measurements within 17% for velocity magnitude, 2 degrees for flow angle, and within 10% for slip.

Abstract

Two-dimensional potential flow was used to determine the velocity field within a laboratory centrifugal pump. In particular, the finite element technique was used to model the impeller and volute simultaneously. The rotation of the impeller within the volute was simulated by using steady-state solutions with the impeller in ten different angular orientations. This allowed the interaction between the impeller and the volute to develop naturally as a result of the solution. The results for the complete pump model showed that there are circumferential asymmetries in the velocity field, even at the design flow rate. Differences in the relative velocity components were as large as 0.12 m/s for the radial component and 0.38 m/s for the tangential component, at the impeller exit. The magnitude of these variations was roughly 25 percent of the magnitude of the average radial and tangential velocities at the impeller exit. These asymmetries were even more pronounced at off-design flow rates. The velocity field was also used to determine the location of the tongue stagnation point and to calculate the slip within the impeller. The stagnation point moved from the discharge side of the tongue to the impeller side of the tongue, as the flow rate increased from below design flow to above design flow. At design flow, values of slip ranged from 0.96 to 0.71, from impeller inlet to impeller exit. For all three types of data (velocity profiles, stagnation point location, and slip factor) comparison was made to laser velocimeter data, taken for the same pump. At the design flow, the computational and experimental results agreed to within 17 percent for the velocity magnitude, and 2 deg for the flow angle. The stagnation point locations coincided for the computational and experimental results, and the values for slip agreed to within 10 percent.