PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 1, 1993Catheterization and Cardiovascular Diagnosis10 citations

Assessment of thallium scintigraphy and echocardiography during dobutamine infusion for the detection of coronary artery disease

View Full Paper
MWMark WarnerJPJohn J. PippinGDGermano DiSciascio

Key Result

Dobutamine thallium SPECT detected significant coronary artery disease in 93% of patients, compared to 62% for dobutamine echocardiography.

Study Design

Type

Observational (n=16)

Structured PICO

Does dobutamine infusion with thallium SPECT and echocardiography accurately detect and localize significant coronary artery disease in patients following cardiac catheterization?

P
Population
16 patients following cardiac catheterization evaluated for coronary artery disease using dobutamine thallium SPECT and echocardiography.
E
Exposure
Dobutamine infusion with non-invasive assessment using thallium SPECT and echocardiography
C
Comparator
Cardiac catheterization (implied reference standard for significant coronary artery disease)
O
Outcome
Detection of significant coronary artery diseasesurrogate

Dobutamine thallium SPECT is highly sensitive and specific for detecting and localizing coronary artery disease, whereas dobutamine echocardiography is less sensitive for screening but may help detect myocardial viability.

Main Result

Absolute Event Rate: 93% vs 62%

Abstract

Dobutamine infusion was performed in 16 patients following cardiac catheterization, and non-invasive assessment was performed with thallium SPECT and echocardiography. Dobutamine thallium scintigraphy was abnormal in 93% of patients with significant coronary artery disease. In addition, individual epicardial vessel involvement was identified by a corresponding perfusion defect with 88% sensitivity and 93% specificity. Dobutamine echocardiography revealed segmental wall motion abnormalities in 62% of patients with significant coronary disease. However, in six patients baseline segmental wall motion abnormalities on echocardiography improved during dobutamine infusion. Dobutamine thallium SPECT is a safe and useful test for the detection and localization of coronary artery disease. Dobutamine echocardiography is less useful in screening for coronary disease, but may detect areas of abnormally functioning myocardium having retained viability.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Warner et al. (1993) conducted an observational in Coronary artery disease (n=16). Dobutamine thallium SPECT vs. Dobutamine echocardiography was evaluated on Detection of significant coronary artery disease. Dobutamine thallium SPECT detected significant coronary artery disease in 93% of patients, compared to 62% for dobutamine echocardiography.

synapsesocial.com/papers/6a93b300bda3c58f3b453e54https://doi.org/10.1002/ccd.1810290207
Ask AI
Helpful
Bookmark
Share
View Full Paper