July 1, 1994Anesthesia & Analgesia42 citations

Comparison of High-Dose Thrombin Time with Activated Clotting Time for Monitoring of Anticoagulant Effects of Heparin in Cardiac Surgical Patients

View Full Paper
JWJiansheng WangCLChung-Yuan LinRKRobert B. Karp

Key Result

High-dose thrombin time (HiTT) correlated with heparin concentration after initial administration and during cardiopulmonary bypass (r = 0.645 and 0.515), whereas ACT lost its linear relationship.

Study Design

Type

Observational (n=30)

Structured PICO

Does the high-dose thrombin time (HiTT) test correlate better with heparin concentration than the activated clotting time (ACT) test in adult cardiac patients undergoing cardiopulmonary bypass?

P
Population
30 adult cardiac patients undergoing cardiac surgery with cardiopulmonary bypass.
E
Exposure
High-dose thrombin time (HiTT) test for monitoring heparin-induced anticoagulation
C
Comparator
Conventional activated clotting time (ACT) test
O
Outcome
Correlation with heparin concentration in vitro and in vivosurrogate

HiTT may be a more reliable assay than ACT for monitoring heparin effects during cardiac surgery, as it remains unaffected by hypothermia and hemodilution during cardiopulmonary bypass.

Main Result

Effect estimate: r = 0.645 and 0.515

Abstract

The activated clotting time (ACT) is routinely used for monitoring of heparin effects during cardiopulmonary bypass (CPB). However, ACT is not a specific assay for heparin and may be influenced by several other factors, which may be misleading with regard to the proper administration of heparin and protamine. In this pilot study, we compared a new test, the high-dose thrombin time (HiTT), with the conventional ACT test for both in vitro and in vivo heparin-induced anticoagulation. Our in vitro results showed that there were heparin dose-dependent increases in ACT and HiTT. Data on 30 adult cardiac patients indicated that HiTT correlated well with heparin concentration both after initial heparin administration and during CPB (r = 0.645 and 0.515). Hypothermia and hemodilution occurring during CPB did not alter HiTT results. ACT also correlated well with both heparin concentration and HiTT before CPB, but the linear relationship was lost during CPB. Our results suggest that HiTT is a useful assay for monitoring heparin effects during cardiac surgery, even during hypothermia and hemodilution.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wang et al. (1994) conducted an observational in Cardiac surgery requiring cardiopulmonary bypass (n=30). High-dose thrombin time (HiTT) vs. Activated clotting time (ACT) was evaluated on Correlation with heparin concentration (r = 0.645 and 0.515). High-dose thrombin time (HiTT) correlated with heparin concentration after initial administration and during cardiopulmonary bypass (r = 0.645 and 0.515), whereas ACT lost its linear relationship.

synapsesocial.com/papers/6a93c5693bc26c9bae37e717https://doi.org/10.1213/00000539-199407000-00003