April 1, 1976Nuclear Fusion11 citations

Observations of internal relaxation oscillations in the Adiabatic Toroidal Compressor

View Full Paper
RSR. R. Smith

Key Points

Key points are not available for this paper at this time.

Abstract

The soft X-ray signal from the Adiabatic Toroidal Compressor (ATC) sometimes exhibits a 10% modulation with a frequency between 1 and 2 kilohertz. The radial profile of the soft X-ray signal and the electron temperature determined by laser scattering indicate that these fluctuations are associated with a limitation of the central electron temperature and a broadening of the temperature profile. By observing changes in the radial dependence of the relaxation oscillation during neutral counter injection, an increase of thirty to fifty percent in the radius where q = 1 has been measured.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

R. R. Smith (1976) studied this question.