PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 18, 2020Journal of sensors and sensor systems14 citationsOpen Access

Metrological characterization and calibration of thermographic cameras for quantitative temperature measurement

View Full Paper
SKS. KönigBGB. GutschwagerRTR. Taubert

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract. We present the metrological characterization and calibration of three different types of thermographic cameras for quantitative temperature measurement traceable to the International Temperature Scale (ITS-90). Relevant technical specifications – i.e., the non-uniformity of the pixel-to-pixel responsivity, the inhomogeneity equivalent temperature difference (IETD), the noise equivalent temperature difference (NETD), and the size-of-source effect (SSE) – are determined according to the requirements given in the series of Technical Directives VDI/VDE 5585. The measurements are performed with the camera calibration facility of the Physikalisch-Technische Bundesanstalt. The data reference method is applied for the determination and improvement of the non-uniformity, leading to an improved IETD for all three cameras. Finally, the cameras are calibrated according to the different procedures discussed in the VDI/VDE 5585 series. Results achieved with the different calibration procedures are compared for each type of camera and among the three cameras. An uncertainty budget for the calibration of each camera is given according to GUM (ISO, 1995) and VDI/VDE 5585.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

König et al. (2020) studied this question.

synapsesocial.com/papers/6a94e1c7b7c083589ab2c03ahttps://doi.org/10.5194/jsss-9-425-2020
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Nonuniformity correction of infrared cameras by reading radiance temperatures with a spatially nonhomogeneous radiation source2016 · 6 citations
  2. 2A large aperture blackbody bath for calibration of thermal imagers2012 · 17 citations
  3. 3Influence Of Nonuniformity On Infrared Focal Plane Array Performance1985 · 192 citations
  4. 4Thermal Infrared Sensors: Theory, Optimisation and Practice2011 · 71 citations
  5. 5Infrared Thermal Imaging: Fundamentals, Research and Applications2010 · 385 citations