October 1, 1989Critical Care Medicine17 citations

Procedural variables which affect activated clotting time test results during extracorporeal membrane oxygenation therapy

View Full Paper
DUDonald L. UdenNPNathaniel R. PaynePKPamela Kriesmer

Key Result

Variations in test volume (0.25 vs. 0.4 ml) and agitation speed (2 vs. 1 shake/sec) significantly affected activated clotting time values (p<0.05) during ECMO.

Structured PICO

Do procedural variables such as test volume and agitation affect activated clotting time (ACT) test results during ECMO therapy in neonatal lambs?

P
Population
8 neonatal lambs monitored during ECMO to determine procedural variables affecting activated clotting time measurements.
I
Intervention
Variations in activated clotting time (ACT) testing procedures (test volume, agitation speed and direction, intermachine and interpersonnel variability)
C
Comparator
Alternative testing procedures (e.g., 0.25 vs 0.4 ml test volume, 2 shakes/sec vs 1 shake/sec agitation speed)
O
Outcome
Activated clotting time (ACT) valuessurrogate

Procedural variables such as test volume and agitation speed significantly affect ACT measurements during ECMO, highlighting the need for standardized monitoring protocols.

Main Result

p-value: p=<.05

Abstract

Hemorrhage secondary to heparin therapy is one of the most serious risks of extracorporeal membrane oxygenation (ECMO). This study determined those variables which affect the precision of activated clotting time (ACT) measurements used to monitor heparin therapy. Heparin therapy of eight neonatal lambs was monitored during ECMO with two Hemochron 400 machines to determine the effects of intermachine variability, test volume, speed and direction of agitation, and interpersonnel variability on ACT values. Test volume (0.25 vs. 0.4 ml) and agitation speed (2 shakes/sec vs. one shake/sec) resulted in significantly different ACT values (p less than .05). The mean matched ACT values determined from different agitation directions (vertical vs. horizontal) or the use of a stepper pipette to measure test volume vs. visual estimation of test volume were not significantly different. Variability in ACT test results is significantly increased by variations in test volume or agitation (speed and direction), intermachine variability, and by interpersonnel technique. These variables should be considered when devising protocols for ACT monitoring and management of heparin therapy.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Uden et al. (1989) studied Extracorporeal membrane oxygenation (ECMO) therapy (n=8). Procedural variables (test volume, agitation speed and direction) vs. Alternative procedural variables (e.g., 0.25 vs 0.4 ml, 2 vs 1 shake/sec) was evaluated on Activated clotting time (ACT) values (p=<.05). Variations in test volume (0.25 vs. 0.4 ml) and agitation speed (2 vs. 1 shake/sec) significantly affected activated clotting time values (p<0.05) during ECMO.

synapsesocial.com/papers/6a9b06bf8b68602cc2896455https://doi.org/10.1097/00003246-198910000-00016