PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 1, 2002Journal of Microelectromechanical Systems202 citations

Batch mode micro-electro-discharge machining

View Full Paper
KTKenichi TakahataYGYogesh B. Gianchandani

Key Points

Key points are not available for this paper at this time.

Abstract

This paper describes a micro-electro-discharge machining (micro-EDM) technique that uses electrode arrays to achieve high parallelism and throughput in the machining. It explores constraints in the fabrication and usage of high aspect ratio LIGA-fabricated electrode arrays, as well as the limits imposed by the pulse discharge circuits on machining rates. An array of 400 Cu electrodes with 20 /spl mu/m diameter was used to machine perforations in 50-/spl mu/m-thick stainless steel. To increase the spatial and temporal multiplicity of discharge pulses, arrays of electrodes with lithographically fabricated interconnect and block-wise independent pulse control resistance-capacitance (RC) circuits are used, resulting in >100/spl times/ improvement in throughput compared to single electrodes. However, it was found to compromise surface smoothness. A modified pulse generation scheme that exploits the parasitic capacitance of the interconnect offers similarly high machining rates and is more amenable to integration. Stainless steel workpieces of 100 /spl mu/m thickness were machined by 100 /spl mu/m/spl times/100 /spl mu/m square cross-section electrodes using in 85 s using an 80-V power supply. Surface smoothness was unaffected by electrode multiplicity. Using electrode arrays with four circuits, batch production of 36 WC-Co gears with 300 /spl mu/m outside diameter and 70 /spl mu/m thickness in 15 min is demonstrated.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Takahata et al. (2002) studied this question.

synapsesocial.com/papers/6a9d8a98ef6cfb4b18fcf124https://doi.org/10.1109/84.993444
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Parallel Discharge with Partitioned Electrode Arrays for Accelerated Batch Mode Micro-EDM2001 · 3 citations
  2. 2Toward a practical computer-aid for thyristor circuit design1980 · 30 citations
  3. 3Stentenna: a micromachined antenna stent for wireless monitoring of implantable microsensors2004 · 36 citations
  4. 4Batch mode micro-EDM for high-density and high-throughput micromachining2002 · 19 citations
  5. 5Evaluation of Charge Transition in a Small Gap Discharge1996 · 19 citations