PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 1, 1993Journal of Trauma and Acute Care Surgery199 citations

Surgical Treatment of Humeral Shaft Fractures—the Basel Experience

View Full Paper
DHDominik HeimFHFelix HerkertPHPeter Heß

Key Result

Open reduction and internal fixation using 4.5-mm dynamic compression plates for humeral shaft fractures achieved excellent or good functional recovery in 87.3% of patients at 1 year.

Study Design

Type

Observational (n=127)

Structured PICO

Does open reduction and internal fixation using 4.5-mm dynamic compression plates improve functional recovery in patients with humeral shaft fractures?

P
Population
127 patients with humeral shaft fractures treated with open reduction and internal fixation using 4.5-mm dynamic compression plates, with 1-year follow-up.
E
Exposure
Open reduction and internal fixation using 4.5-mm dynamic compression plates (DCP)
O
Outcome
Clinical and radiological functional recovery at 1 yearpatient reported

Plate fixation of humeral shaft fractures provides excellent or good functional recovery in the vast majority of selected patients, representing a viable alternative to conservative treatment.

Abstract

One hundred twenty seven patients with fractures of the humeral shaft were treated by open reduction and internal fixation using 4.5-mm dynamic compression plates (DCP). Seventy one osteosyntheses were performed primarily, 36 following attempted closed reduction, and 20 secondarily after a failed conservative treatment of about 8 weeks. A primary radial nerve palsy was present in 19 patients, and appeared subsequently in four additional patients. One hundred two of the 127 patients could be clinically and radiologically examined 1 year after internal fixation: 89 patients (87.3%) had excellent or good results with full functional recovery. Thirteen patients (12.7%) showed a limited range of motion of either the shoulder or elbow or both. This was mostly because of other fractures of the same limb or persistent neurologic impairment. We observed two transitory postoperative nerve palsies, five early failures of internal fixation because of technical errors, two pseudarthroses and four postoperative infections, which healed with one exception by suction drainage and early removal of the plate. We conclude that a correct plate fixation of humeral shaft fractures in a selected group of patients represents an alternative to conservative treatment with the advantage of greater patient comfort.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Heim et al. (1993) conducted an observational in Humeral shaft fractures (n=127). Open reduction and internal fixation using 4.5-mm dynamic compression plates (DCP) was evaluated on Excellent or good results with full functional recovery. Open reduction and internal fixation using 4.5-mm dynamic compression plates for humeral shaft fractures achieved excellent or good functional recovery in 87.3% of patients at 1 year.

synapsesocial.com/papers/6aa3bfe6240321efda555545https://doi.org/10.1097/00005373-199308000-00009
Ask AI
Helpful
Bookmark
Share
View Full Paper