PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 1, 1989The American Journal of Cardiology154 citationsOpen Access

Comparison of time- and frequency domain-based measures of cardiac parasympathetic activity in Holter recordings after myocardial infarction

View Full Paper
JBJ. Thomas BiggerPAPaul AlbrechtRSRichard C. Steinman

Key Result

The abstract outlines the objective to determine the strength of association among three measures of tonic vagal activity after myocardial infarction, but reports no quantitative results.

Study Design

Type

Observational

Structured PICO

P
Population
Patients after myocardial infarction
E
Exposure
Measurement of time- and frequency domain-based measures of cardiac parasympathetic activity (high frequency band 0.15 to 0.50 Hz, pNN50, and r-MSSD) from Holter recordings
O
Outcome
Strength of association (correlation) among 3 measures of tonic vagal activity: the high frequency band, pNN50, and r-MSSDsurrogate

This study aimed to determine if time-domain and frequency-domain measures of tonic vagal activity in Holter recordings are strongly correlated enough to be used interchangeably in post-myocardial infarction patients.

Abstract

Abstract The standard deviation of normal RR intervals predicts mortality after acute myocardial infarction independently of left ventricular function and ventricular arrhythmias. 1 Myers et al 2 suggested that this measure of heart period variability is a broad-band measure composed of high and low frequency components, and suggested that patients with malignant arrhythmias have reduced power in the high frequency band of the heart period or heart rate power spectrum. The high frequency band of the heart rate power spectrum reflects vagally mediated respiratory sinus arrhythmia. 3–5 Also, 2 time domain measures—the percent of absolute differences between successive normal RR intervals that exceed 50 ms (pNN50) and the root mean square successive difference (r-MSSD)—have been used as measures of tonic vagal activity. 6 The objective of this study was to determine the strength of association among 3 measures of tonic vagal activity: the high frequency band (0.15 to 0.50 Hz) in the heart period power spectrum, pNN50 and r-MSSD. We expected strong correlations among these 3 variables, and hoped that the correlations would be strong enough to permit their interchangeable use for assessing tonic vagal activity in long duration electrocardiographic recordings. We expected weaker correlations of these 3 measures with measures of total heart rate or heart period variability, such as the standard deviation of normal RR intervals or the total power in the heart period power spectrum.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bigger et al. (1989) conducted an observational in myocardial infarction. Measures of tonic vagal activity (high frequency band, pNN50, r-MSSD) was evaluated on Strength of association among 3 measures of tonic vagal activity. The abstract outlines the objective to determine the strength of association among three measures of tonic vagal activity after myocardial infarction, but reports no quantitative results.

synapsesocial.com/papers/6aa5b151b3a9aaf5308e3a85https://doi.org/10.1016/0002-9149(89)90436-0
Ask AI
Helpful
Bookmark
Share
View Full Paper