Sediment buildup in storage tanks over extended operation periods may compromise their efficiency. To prevent pollutant deposition in storage tanks and enhance their hydraulic self-cleaning efficiency, this study addressed the unique structural configuration of lateral flow in storage tanks. Conducting numerical simulations to investigate the hydraulic characteristics within storage tanks, an integrated approach combining physical experiments and response surface methodology (RSM) was employed to optimize flow distribution. Key findings reveal that tangential and normal velocity differences lead to flow distribution nonuniformity, exacerbated by increased inflow Froude number (Fr) and reduced relative weir height (hi). Based on the flow-splitting mechanism, an optimized “combined raised baffle” was proposed. Through single-factor experiments, Plackett–Burman (PB) screening, and RSM experiments, the optimal combination for maximal flow uniformity was determined as h1 = 1.27, h2 = 1.23, and h3 = 1.24, achieving an 87.18% improvement in Qy compared to the initial design. After optimization, the incoming flow pattern of the inlet channel of the storage pond was improved, and the difference between tangential and normal flow velocity in the flow field was significantly reduced. This research provides a novel approach and methodological paradigm for optimizing storage tanks and other hydraulic structures, demonstrating significant academic and engineering value.
Gao et al. (Mon,) studied this question.