Composite steel bridges in the United Sates are typically constructed using 22 mm-diameter (7/8 in.-diameter) shear studs. The number of shear studs on a girder can be significantly reduced by using larger-diameter studs. This study employed 11 push-out tests to investigate the static performance of 29 mm-diameter (1-1/8 in.-diameter) shear studs. An extensive welding investigation was conducted to develop the optimum welding parameters for 29 mm-diameter studs. Results from experiments showed the static strength of 29 mm-diameter studs satisfied stud strength equations in the AASHTO LRFD Bridge Design Specifications and Eurocode 4. The ductility of the 29 mm studs was comparable or better than that of 22 mm-diameter shear studs. Concrete cracking under service level loading was similar between specimens with 22 and 29 mm studs. Observations indicate that the minimum allowable stud penetration into the concrete deck may need to increase in order for the 29 mm-diameter studs to have good static performance. Using partial-depth precast concrete panels in the bridge deck reduced the static strength of both 22 and 29 mm-diameter shear studs in push-out specimens.
Deng et al. (Fri,) studied this question.