This work proposes an intelligent strategy for the coordinated management of active and reactive power in Battery Energy Storage Systems (BESSs) within AC microgrids operating under both grid-connected (GCM) and islanded (IM) modes to minimize daily operational costs. The problem is formulated as a mixed-variable optimization model that explicitly leverages the control capabilities of BESS power converters. To solve it, a Parallel Particle Swarm Optimization (PPSO) algorithm is employed, coupled with a Successive Approximation (SA) power flow solver. The proposed approach was benchmarked against parallel implementations of the Crow Search Algorithm (PCSA) and the JAYA algorithm (PJAYA), both in parallel, using a realistic 33-node AC microgrid test system based on real demand and photovoltaic generation profiles from Medellín, Colombia. The strategy was evaluated under both deterministic conditions (average daily profiles) and stochastic scenarios (100 daily profiles with uncertainty). The proposed framework is evaluated on a 33-bus AC microgrid that operates in both grid-connected and islanded modes, with a battery energy storage system dispatched at both active and reactive power levels subject to network, state-of-charge, and power-rating constraints. Three population-based optimization algorithms are used to coordinate BESS schedules, and their performance is compared based on daily operating cost, BESS cycling, and voltage profile quality. Quantitatively, the PPSO strategy achieved cost reductions of 2.39% in GCM and 1.62% in IM under deterministic conditions, with a standard deviation of only 0.0200% in GCM and 0.2962% in IM. In stochastic scenarios with 100 uncertainty profiles, PPSO maintained its robustness, reaching average reductions of 2.77% in GCM and 1.53% in IM. PPSO exhibited consistent robustness and efficient performance, reaching the highest average cost reductions with low variability and short execution times in both operating modes. These findings indicate that the method is well-suited for real-time implementation and contributes to improving economic outcomes and operational reliability in grid-connected and islanded microgrid configurations. The case study results show that the different strategies yield distinct trade-offs between economic performance and computational effort, while all solutions satisfy the technical limits of the microgrid.
Sanín-Villa et al. (Wed,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: