Background/Objectives: Electroencephalography (EEG) is a promising modality for fatigue detection because it directly reflects neural states; however, it is hindered by the need for subject-specific calibration and its reliance on unstable labeling. Moreover, classical EEG features are sensitive to intrinsic brain rhythm variations, causing pronounced domain shifts that degrade performance across sessions and subjects. Methods: Motivated by the biological fatigue rebound mechanism, we propose a robust cross-subject metric which we name Short-Term Second-Order Differential Entropy (ST-SODE). ST-SODE effectively suppresses the interference of background brain rhythms, enhancing robustness to cross-domain drift; consequently, its one-dimensional output can provide an indication of fatigue states without additional model training. Results: ST-SODE is validated on the public driving fatigue regression dataset SEED-VIG and on a private Vigilance classification dataset based on the N-Back task. ST-SODE achieves a correlation coefficient of 0.56 on SEED-VIG dataset (vs. 0.4 for differential entropy, DE) and a binary classification accuracy of 93.75% on the Vigilance dataset, outperforming other EEG-based fatigue metrics. Conclusions: ST-SODE offers a reliable solution for deployment in fields such as driving, manufacturing, and healthcare, where it could reduce safety incidents caused by fatigue.
Li et al. (Sat,) studied this question.