Does the reverse Barbeau test accurately detect post-procedural radial artery occlusion compared to duplex ultrasonography in patients undergoing transradial coronary catheterization?
The reverse Barbeau test is comparable to duplex ultrasonography for detecting complete radial artery occlusion after transradial catheterization, supporting its use as a simple first-line detection method.
The transradial approach is recommended as a first choice in coronary catheterizations and interventions, for among other reasons, the reduction in the number of local complications. A head-to-head comparison of the reverse Barbeau test (RBT) and duplex ultrasonography (DUSG) for the detection of post-procedural radial artery patency and occlusion has not yet been evaluated. In 500 patients from our same-day discharge program (age 65 ± 9.4 years, 148 women), radial artery patency and occlusion, compression time, haematomas, and other local complications were evaluated. Radial artery patency was confirmed in 495 patients (99.0%), and complete radial artery occlusion (RAO) was detected in 2 (0.4%) patients using both methods. In 3 patients (0.6%), the RBT was negative, while incomplete RAO was detected by DUSG. Superficial haematomas (˃ 5 but ≤10 cm) were found in 27 (5.4%) patients. There were no other local complications. Detection of radial artery patency and occlusion using the RBT and DUSG was comparable. The incidence of RAO in our study was extremely low. Thanks to its simplicity, the RBT has the potential to be used as the first method of detection of radial occlusion after coronary catheterizations.
Jirouš et al. (Wed,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: