Very late recurrence of atrial fibrillation after ablation was associated with weight >200 lbs, fewer isolated pulmonary veins, and the presence of non-PV triggers (OR 3.4; 95% CI 1.3-8.7; P=0.01).
Case-Control (n=246)
No
What are the clinical and procedural predictors of very late recurrence of atrial fibrillation after radiofrequency catheter ablation?
Very late recurrence of atrial fibrillation after ablation is associated with higher body weight, presence of non-pulmonary vein triggers, and incomplete pulmonary vein isolation during the initial procedure.
Effect estimate: OR 3.4 (95% CI 1.3-8.7)
Absolute Event Rate: 30% vs 11%
p-value: p=0.01
INTRODUCTION: Radiofrequency catheter ablation can effectively treat patients with refractory atrial fibrillation (AF). Very late AF recurrence (> or = 12 months post-ablation) is uncommon and may represent a unique patient cohort. METHODS AND RESULTS: A nested case-control study was performed in the cohort who underwent AF ablation at the University of Pennsylvania to characterize patients who develop very late AF recurrence after ablation. The procedure consisted of isolation of pulmonary veins (PVs) demonstrating triggers and elimination of non-PV triggers initiating AF. Twenty-seven (7.9%) patients with very late recurrence were compared to 219 patients without recurrence and > or = 12 months of follow-up. The mean age was 54.6 +/- 11.3 years and 79% were men. Very late recurrence patients more likely weighed >200 lbs (70% vs 55%, P = 0.01); during initial ablation had fewer PVs isolated (2.8 +/- 1.1 vs 3.3 +/- 1.0, P = 0.03); and were less likely to have right inferior PV isolation (37% vs 61%, P = 0.02), less likely to have isolation of all PVs (30% vs 56%, P = 0.01), and more likely to have non-PV triggers (30% vs 11% OR 3.4(95% CI, 1.3-8.7), P = 0.01). PV reconnectivity and new triggers were found in the majority of patients with very late recurrence of AF who underwent repeat ablation. CONCLUSION: Very late recurrence of AF more likely occurred in patients >200 lbs who demonstrated non-PV triggers and did not undergo right inferior PV isolation. The majority of patients undergoing repeat ablation for very late recurrence demonstrated PV reconnectivity and new non-PV and PV triggers not observed during the initial ablation.
Mainigi et al. (Wed,) conducted a case-control in Atrial fibrillation (n=246). Very late AF recurrence (≥12 months post-ablation) vs. No recurrence was evaluated on Presence of non-pulmonary vein triggers during initial ablation (OR 3.4, 95% CI 1.3-8.7, p=0.01). Very late recurrence of atrial fibrillation after ablation was associated with weight >200 lbs, fewer isolated pulmonary veins, and the presence of non-PV triggers (OR 3.4; 95% CI 1.3-8.7; P=0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: