A switching control strategy to extend the soft-switching operating range of the dual active bridge (DAB) dc-dc converter under the zero-voltage-switching (ZVS) operating mode is proposed. The converter topology consists of two active bridges linked by a high-frequency transformer. One drawback of this strategy is that soft-switching is only possible in a restricted converter operating region. A novel pulse width modulation strategy to extend the conventional soft-switching operating mode region and its analysis are presented in this paper. Experimental results are given in order to validate the theoretical analysis and practical feasibility of the proposed strategy.