Los puntos clave no están disponibles para este artículo en este momento.
A combination of cyclic polarization tests, electrochemical impedance spectroscopy, and electrochemical quartz crystal microbalance (EQCM) measurements indicate a film is formed when aluminum is polarized above 4. 5V in 1: 1 EC+DMC with 1M LiBOB. The quantity of film that is formed increases with increasing applied potential. Results of EQCM tests suggest the film is AlBOsub 3. The film is very protective against corrosion and inhibits pitting corrosion of aluminum in normally corrosive 1M LiTFSI.
Zhang et al. (Sun,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: