A combination of cyclic polarization tests, electrochemical impedance spectroscopy, and electrochemical quartz crystal microbalance (EQCM) measurements indicate a film is formed when aluminum is polarized above 4.5V in 1:1 EC+DMC with 1M LiBOB. The quantity of film that is formed increases with increasing applied potential. Results of EQCM tests suggest the film is AlBO{sub 3}. The film is very protective against corrosion and inhibits pitting corrosion of aluminum in normally corrosive 1M LiTFSI.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2006) studied this question.