July 22, 2013Pacing and Clinical Electrophysiology4 citations

Radiofrequency Ablation at Low Irrigation Flow Rates Using a Novel 12‐Hole Gold Open‐Irrigation Catheter

FAFerdi AkcaEZEndre ZimaÉVÉ. Végh

Structured PICO

Does a novel 12-hole gold open-irrigation catheter improve lesion size and safety at low irrigation flow rates compared to a platinum-iridium catheter in a canine thigh muscle model?

P
Population
103 lesions created on the thigh muscle of 5 mongrel dogs (in vivo animal model)
I
Intervention
Radiofrequency ablation using a novel 12-hole irrigated gold-tip (Au) catheter (7F/3.5-mm electrode) at 30 W for 60 seconds with low irrigation flow rates (8 mL/min and 15 mL/min)
C
Comparator
Radiofrequency ablation using a standard six-hole irrigated platinum-iridium (PtIr) catheter (7F/3.5-mm electrode) at 30 W for 60 seconds with 8 mL/min and 15 mL/min irrigation
O
Outcome
Presence of coagulum on the tissue surface at the lesion location after completion of an RF applicationsafety

A novel 12-hole gold irrigated-tip catheter allows for safe radiofrequency ablation at lower irrigation flow rates while creating larger lesions compared to a standard platinum-iridium catheter in an animal model.

Limitations

  • Animal model where contact force and stability differ from clinical situations in the human heart
  • Ablation was only performed using 30 W power for 60 seconds, leaving safety at higher power settings unclear
  • The six-hole irrigated tip used as a reference is no longer the industry standard
  • Cannot fully differentiate between the effects of the conductive properties of gold versus the novel 12-hole catheter design

Abstract

BACKGROUND: High irrigation rates during radiofrequency (RF) ablation may cause fluid overload and limit lesion size. This in vivo animal study assessed the safety and efficacy of RF ablation at low irrigation rates using a novel 12-hole gold catheter. METHODS: A total of 103 lesions, created on the thigh of five mongrel dogs, were analyzed. Lesions were created using a 12-hole irrigated gold-tip (Au) and a six-hole irrigated platinum-iridium (PtIr) catheter (both 7F/3.5-mm electrode; BIOTRONIK SE 15 mL/min: 36.0 ± 1.5°C vs 46.9 ± 5.4°C, P < 0.0001) and perpendicular position (15 mL/min: 35.5 ± 1.2°C vs 38.4 ± 2.5°C, P = 0.003). The number of steam pops between Au and PtIr was comparable for parallel (8 mL/min: 14% vs 27%, P = 0.65; 15 mL/min: 14% vs 43%, P = 0.21) and perpendicular orientation (8 mL/min: 25% vs 17%, P = 1.00; 15 mL/min: 18% vs 0%, P = 0.48). Au created larger volumes than PtIr at 8 mL/min irrigation (861 ± 251 mm(3) vs 504 ± 212 mm(3) , P = 0.004); however, for 15 mL/min, volumes were comparable (624 ± 269 mm(3) vs 768 ± 466 mm(3) , P = 0.46). No coagulum formation was observed for any of the catheters on the surface and catheter tip. CONCLUSION: RF ablation at low flow rate using a novel 12-hole irrigation Au catheter is safe and results in larger lesions than with a PtIr electrode.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Akca et al. (2013) studied this question.

synapsesocial.com/papers/6a7f27c763e03285017c9d12https://doi.org/10.1111/pace.12215
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Radiofrequency Catheter Ablation Using Cooled Electrodes: Impact of Irrigation Flow Rate and Catheter Contact Pressure on Lesion Dimensions2002 · 102 citations
  2. 2Comparative study of lesions obtained with radiofrequency between irrigated ablation catheter with flexible tip and non-irrigated catheter in ex vivo porcine heart slices2024
  3. 3High‐Volume Lesions Using a New Second‐Generation Open Irrigation Radiofrequency Catheter Are Associated with the Development of Inhomogeneous Lesions2014 · 8 citations
  4. 4Comparative Study of Lesions Obtained through Radiofrequency between the Irrigated Ablation Catheter with a Flexible Tip and the Non-Irrigated Catheter in Ex Vivo Porcine Hearts2024 · 2 citations
  5. 5Effect of Irrigant Characteristics on Lesion Formation After Radiofrequency Energy Delivery Using Ablation Catheters with Actively Cooled Tips2015 · 102 citations