This paper introduces a novel Lithium-Ion Battery (LIB) State-of-Charge (SOC) estimation approach that integrates Akima–Savitzky–Golay curve reconstruction with a Bayesian-optimized, adaptive Extended Kalman Filter (EKF). The method addresses crucial SOC estimation challenges by means of three foundational advancements: (i) a refined open-circuit voltage (OCV)-SOC curve reconstruction grounded in Akima interpolation coupled with Savitzky–Golay filtering, (ii) an adaptive EKF weighting strategy, and (iii) systematic hyperparameter value optimization executed through Bayesian optimization. Comprehensive performance validation utilizes an extensive dataset collected from LG HG2 18650 cells across temperatures of −20 °C to 40 °C, incorporating multiple standard driving cycles—namely HPPC, UDDS, HWFET, LA92, and US06 cycles. The proposed method achieves an improved estimation accuracy with an average Root Mean Square Error (RMSE) of 2.65% over the different operating conditions and temperature variations. Notably, the method markedly enhances SOC estimation reliability in the critical mid-SOC range (20–80%), while preserving the computational overhead necessary for real-time integration into Battery Management Systems (BMSs). The adaptive weighting successfully compensates for the present physical limitations, thereby delivering a resilient SOC estimation tailored for Electric Vehicle (EV) battery applications.