Background/Objectives: The uprighting of mesially tipped mandibular second molars following first molar loss is a complex surgical and orthodontic challenge. Conventional methods often result in reciprocal anchorage loss. Mini-implants (MIs) have emerged as essential temporary anchorage devices (TADs) that provide absolute anchorage and enable more predictable tooth movements. Methods: Numerical simulations were performed to evaluate the forces required for mandibular second molar uprighting under two conditions: first, only with the second molar present, and second, with both the second and the third molars present. Although the periodontal ligament exhibits nonlinear and viscoelastic behavior in vivo, a linear elastic approximation was adopted to allow for a reliable evaluation of comparative stress distribution and initial displacement patterns within the scope of this exploratory biomechanical study. Stress distribution in the roots, periodontal ligament, and alveolar bone was assessed for each scenario. Two three-dimensional (3D) models of the left mandibular segment were created from scans of a human mandible and its teeth. The first model included the canine, the first and second premolars, and the second molar. A second model additionally incorporated the third molar. A retromolar MI was placed in both models. Molar uprighting was simulated using a spring connecting the implant to a button bonded on the mesial surface of the second molar. A force of 200 g was applied because in clinical orthodontic practice, forces that exceed approximately 2 N may cause pain or undesirable tooth mobility. Displacements along the X, Y, and Z axes, as well as regions of peak stress, were analyzed. Results: Model 1 showed maximum displacements at the furcation/mid-root, distal root apex, and distal crown, with von Mises stresses of 0.470 to 0.371 MPa. In Model 2, peak displacements occurred at the mesial root and crown, with stresses of 0.185 and 0.149 MPa, respectively. The magnitude of displacements was in the order of 10−5 mm. Such values represent initial mechanical responses rather than clinically observable tooth movements. However, the differences between models (e.g., the stress reduction) are expected to be clinically meaningful. Conclusions: Since clinical measurements regarding the stress distribution on teeth and surrounding tissues during orthodontic molar uprighting movements are impossible to perform, the finite element method (FEM) can offer insight into these aspects. The presence of the third molar significantly modulates the biomechanics of second molar uprighting via retromolar MIs. When the third molar is present, the second molar exhibits a reduced tendency for deformation during distalization, although this leads to a slower displacement. This FEM provides biomechanical insights but does not support direct clinical decision-making. The present findings should be viewed as theoretical biomechanical tendencies that require confirmation through clinical, experimental, and longitudinal studies before translation into clinical practice.
Nica et al. (Fri,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: