Atrial sites displaying a greater percentage of continuous electrical activity (P=0.016) or a temporal activation gradient (P=0.038) independently predicted slowing or termination of chronic AF.
Observational (n=40)
What electrogram characteristics predict slowing or termination of chronic atrial fibrillation during catheter ablation?
Catheter ablation at sites displaying a greater percentage of continuous activity or a temporal activation gradient is associated with slowing or termination of chronic AF.
p-value: p=0.016 and 0.038
OBJECTIVES: This study sought to determine the characteristics of atrial electrograms predictive of slowing or termination of atrial fibrillation (AF) during ablation of chronic AF. BACKGROUND: There is growing recognition of a role for electrogram-based ablation. METHODS: Forty consecutive patients (34 male, 59 +/- 10 years) undergoing ablation for chronic AF persisting for a median of 12 months (range 1 to 84 months) were included. After pulmonary vein isolation and roof line ablation, electrogram-based ablation was performed in the left atrium and coronary sinus. Targeted electrograms were acquired in a 4-s window and characterized by: 1) percentage of continuous electrical activity; 2) bipolar voltage; 3) dominant frequency; 4) fractionation index; 5) mean absolute value of derivatives of electrograms; 6) local cycle length; and 7) presence of a temporal gradient of activation. Electrogram characteristics at favorable ablation regions, defined as those associated with slowing (a >or=6-ms increase in AF cycle length) or termination of AF were compared with those at unfavorable regions. RESULTS: The AF was terminated by electrogram-based ablation in 29 patients (73%) after targeting a total of 171 regions. Ablation at 37 (22%) of these regions was followed by AF slowing, and at 29 (17%) by AF termination. The percentage of continuous electrical activity and the presence of a temporal gradient of activation were independent predictors of favorable ablation regions (p = 0.016 and p = 0.038, respectively). Other electrogram characteristics at favorable ablation regions were not significantly different from those at unfavorable ablation regions. CONCLUSIONS: Catheter ablation at sites displaying a greater percentage of continuous activity or a temporal activation gradient is associated with slowing or termination of chronic AF.
Takahashi et al. (Sat,) conducted a observational in Chronic atrial fibrillation (n=40). Electrogram characteristics (continuous electrical activity and temporal gradient of activation) vs. Unfavorable ablation regions (without these characteristics) was evaluated on Favorable ablation regions (associated with slowing or termination of atrial fibrillation) (p=0.016 and 0.038). Atrial sites displaying a greater percentage of continuous electrical activity (P=0.016) or a temporal activation gradient (P=0.038) independently predicted slowing or termination of chronic AF.