PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 1, 2000British Journal of Sports Medicine79 citationsOpen Access

The slow component of Vo2in professional cyclists

View Full Paper
ALAlejandro Lucı́aJHJesús HoyosJCJosé López Chicharro

Key Result

During constant load heavy exercise, professional cyclists exhibited a small VO2 slow component (130 ml in 17 minutes) without significant changes in neuromuscular activity (P>0.05).

Study Design

Type

Observational (n=9)

Structured PICO

P
Population
9 professional road cyclists (mean age 26 years; VO2max 72.6 ml/kg/min)
I
Intervention
20 minute cycle ergometer tests performed at about 80% of VO2MAX
O
Outcome
Magnitude of the slow component of oxygen uptake (VO2) and neuromuscular activity (assessed by surface EMG)surrogate

In professional cyclists, constant load heavy exercise induces a small VO2 slow component that does not appear to be driven by altered neuromuscular activity.

Abstract

OBJECTIVES: To analyse the slow component of oxygen uptake (VO2) in professional cyclists and to determine whether this phenomenon is due to altered neuromuscular activity, as assessed by surface electromyography (EMG). METHODS: The following variables were measured during 20 minute cycle ergometer tests performed at about 80% of VO2MAX in nine professional road cyclists (mean (SD) age 26 (2) years; VO2max 72.6 (2.2) ml/kg/min): heart rate (HR), gas exchange variables (VO2, ventilation (VE), tidal volume (VT), breathing frequency (fb), ventilatory equivalents for oxygen and carbon dioxide (VE/VO2 and VE/VCO2 respectively), respiratory exchange ratio (RER), and end tidal PO2 and PCO2 (PETO2 and PETCO2 respectively)), blood variables (lactate, pH, and HCO3-) and EMG data (root mean from square voltage (rms-EMG) and mean power frequency (MPF)) from the vastus lateralis muscle. RESULTS: The mean magnitude of the slow component (from the end of the third minute to the end of exercise) was 130 (0.04) ml in 17 minutes or 7.6 ml/min. Significant increases from three minute to end of exercise values were found for the following variables: VO2 (p0.05) throughout the exercise tests. CONCLUSIONS: A significant but small VO2 slow component was shown in professional cyclists during constant load heavy exercise. The results suggest that the primary origin of the slow component is not neuromuscular factors in these subjects, at least for exercise intensities up to 80% of VO2MAX.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lucı́a et al. (2000) conducted an observational in Professional road cyclists (n=9). 20 minute cycle ergometer tests at about 80% of VO2MAX was evaluated on Magnitude of the slow component of oxygen uptake (VO2) and neuromuscular activity (rms-EMG and MPF). During constant load heavy exercise, professional cyclists exhibited a small VO2 slow component (130 ml in 17 minutes) without significant changes in neuromuscular activity (P>0.05).

synapsesocial.com/papers/6a075f7f72f0218126583a78https://doi.org/10.1136/bjsm.34.5.367
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Influence of endurance training and catecholamines on exercise &OV0312;O2 response1994 · 24 citations
  2. 2Heart Rate Response to Professional Road Cycling: The Tour de France2007 · 183 citations
  3. 3Effects of infused epinephrine on slow phase of O2 uptake kinetics during heavy exercise in humans1994 · 64 citations
  4. 4Reliability and Validity of a Continuous Incremental Treadmill Protocol for the Determination of Lactate Threshold, Fixed Blood Lactate Concentrations, and VO2max1990 · 195 citations
  5. 5Effects of Blood Gas, pH, Lactate, Potassium on the Oxygen Uptake Time Courses during Constant-Load Bicycle Exercise.1992 · 14 citations