Enhancing thermal mixing efficiency in electric water heaters through inverted cup designs: a comprehensive CFD analysis with experimental validation

MFMahmoud FouadMRMostafa RizkANAnoud Nagaf

Key Points

  • This research aims to explore innovative inverted cup designs to enhance thermal mixing efficiency in electric water heaters.
  • Conducted CFD analysis with a three-dimensional model of electric water heater tanks.
  • Validated numerical models against experimental data and evaluated four distinct inverted cup configurations.
  • Assessed the thermal mixing performance based on outlet temperature and mixing efficiency.
  • Design 4 achieved the target outlet temperature of 313.15 K in only 647.29 s, a 3.6% improvement over conventional designs.
  • Enhanced turbulent mixing and reduced thermal stratification were observed with optimized geometries.
  • Validation against an experimental HVAC case demonstrated discrepancies within 0.5 K, confirming the reliability of the simulations.

Abstract

Abstract This study presents a comprehensive computational fluid dynamics (CFD) investigation into thermal mixing enhancement in electric water heaters (EWHs) using innovative inverted cup designs. The research integrates parametric design analysis with rigorous numerical validation to establish reliable simulation methodologies for thermal-fluid systems. A three-dimensional (3D) model of a standard EWH tank was developed and validated against experimental data, followed by systematic evaluation of four inverted cup configurations (Designs 1–4) with varying geometric parameters. Results demonstrate that Design 4 (20–80-60) achieves the target outlet temperature of 313 . 15 K in only 647 . 29 s, representing a 3 . 6% improvement over the conventional nozzle de-sign. Temperature contours and velocity vector analyses reveal enhanced turbulent mixing and reduced thermal stratification with optimized cup geometries. Furthermore, the numerical methodology was rigorously validated through reproduction of an experimental HVAC test case, showing excellent agreement with measured data (discrepancies within 0 . 5 K) and confirming mesh independence beyond 680,000 cells. This research provides valuable insights into passive mixing enhancement techniques for EWHs and establishes a validated computa-tional framework for thermal system optimization, contributing to energy efficiency improvements in residential water heating applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fouad et al. (2026) studied this question.

synapsesocial.com/papers/6a1295bf48a0ea1665672099https://doi.org/10.1186/s44147-026-01040-4
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Experimental and Numerical Analysis of Thermal Efficiency Improvement in a Hybrid Solar–Electric Water Heating System2026
  2. 2Evaluation of Thermal Mixing in T-Junctions Using Computational Fluid Dynamics (CFD)2025
  3. 3Integrated CFD and Experimental Approach for Thermal Performance Evaluation of a Tubular Minijet Heat Exchange2025
  4. 4Optimization of a fin-and-tube latent thermal energy storage for domestic hot water application2026
  5. 5An Experimental and Numerical Investigation of a Heat Exchanger for Showers2024 · 5 citations