Vortex-induced vibrations (VIVs) pose significant risks to the structural integrity of subsea cables and pipelines under free-span conditions. It is extremely helpful to be able to screen for VIV and understand for a particular cable or pipeline what the minimum free-span threshold lengths are beyond which in-line and/or cross-flow VIV can be excited, causing fatigue problems. To date screening is a more complex and detailed task. This paper introduces a universal dimensionless velocity, V*, and one graph that can be used across all types of VIV free spans to quickly assess minimum free-span threshold lengths. Natural frequencies are not required to be calculated for screening each time, as they are implicit in the curve. The universal criteria are developed via non-dimensional analysis to establish the significant physical mechanisms, after which the relationships are populated, forming a single curve for in-line and for cross-flow VIV with a typical mass ratio and a conservative zero as-laid tension case.
Marcollo et al. (Tue,) studied this question.