Experiment analyzed sensing characteristics of flexible piezoelectric films under loads and temperatures, indicating high sensitivity and signal stability.
Abstract Flexible thin-film sensors exhibit considerable application potential in the structural health monitoring of bridges under complex traffic scenarios, owing to their capability of rapidly responding to dynamic loads, static loads, and dynamic-static coupled loads. In this study, following the evaporation crystallization method, ZnO/PVA was deposited on the substrate to form a 10-µm-thick film by adjusting the material ratio (m(ZnO):m(PVA) = 4:1) and solution environment (pH = 12). After cutting and packaging, the flexible piezoelectric film sensor was obtained. The sensing characteristics of the ZnO/PVA film sensor under quasi-static, vibratory, and coupled-force loads were analyzed using a dynamic data acquisition system, revealing excellent response feedback in detecting these three stress states. the sensitivity, linearity, and electrical output response time (at 25°C) were 1.33, 0.38, and 14.44 mV/N; 2.1, 5.1, and 5.3%; and 50, 5, and 8 ms, respectively. Temperature-dependent tests (10–60°C) demonstrated significant signal stability after implementing a curve-fitting compensation algorithm (R²=0.998). This temperature correction mechanism addresses the critical challenge of environmental fluctuations in practical bridge monitoring scenarios where static stresses and dynamic vibrations coexist.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: