PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 13, 202526 citations

Shortwave Infrared Hemicyanine-6 for Cancer-Activated and Shaving-Free Preclinical Imaging of Lung Metastasis.

View Full Paper
HYHanyu YangDLDong‐Hao LiJWJiayan Wu

Key Points

  • HCS6 provides the longest emission maximum at 1010 nm, showcasing superior photostability for imaging.
  • This study presents a method to create six hemicyanine derivatives for enhanced SWIR fluorescence.
  • HCS6 enables deep-tissue imaging in mice without shaving, improving practical applications.
  • Activatable probes in the SWIR range could significantly advance early detection of lung metastasis.

Abstract

Fluorescence imaging in the shortwave infrared (SWIR) window enables deeper tissue and higher-contrast visualization of pathological events compared to that in the conventional near-infrared (NIR) window. However, specific SWIR detection of biomarkers of interest remains challenging because few fluorophore scaffolds are available to be further modified into biomarker-activatable SWIR probes. Herein, we employ a highly efficient approach to synthesize six hemicyanine derivatives with emissions extending to the SWIR region and structural amenability for construction of activatable probes. The bathochromic shifts of these dyes are driven by the extension of the central polymethine bridge and the substitution of the xanthene endocyclic oxygen atom with a heavier sulfur atom. Among all fluorophores, HCS6, featuring three central methine-methine bonds, has the longest emission maximum at 1010 nm along with superior photostability and high SWIR brightness. These properties enable HCS6 to achieve lung imaging in haired mouse models without the need for shaving. Furthermore, HCS6 is constructed into an activatable probe that selectively turns on its SWIR fluorescence in response to a cancer-associated biomarker, allowing for the highly sensitive identification of metastatic lung lesions in unshaved mice. These hemicyanine scaffolds offer a promising platform for developing versatile activatable probes, highlighting their potential for SWIR microscopy and deep-tissue biological imaging.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yang et al. (2025) studied this question.

synapsesocial.com/papers/689e03e9d61984b91e13d393https://doi.org/10.1021/jacs.5c06682
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Solvatochromic Dyes as Solvent Polarity Indicators1994 · 5,509 citations
  2. 2Fundamentals in the chemistry of cyanine dyes: A review2017 · 308 citations
  3. 3Reactive species involved in the regioselective photooxidation of heptamethine cyanines2015 · 166 citations
  4. 4Singlet oxygen: there is indeed something new under the sun2010 · 1,273 citations
  5. 5Contrast-noise-ratio (CNR) analysis and optimisation of breast-specific gamma imaging (BSGI) acquisition protocols2013 · 54 citations