PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 14, 2025Alzheimer s & Dementia27 citationsOpen Access

Comparison of plasma p‐tau217/Aβ42, p‐tau217, and Aβ42/Aβ40 biomarkers by race to detect Alzheimer's disease

View Full Paper
KCKatheryn A Q CousinsMKMagdalena KoreckaYWYang Wan

Key Points

  • Plasma p-tau217/Aβ42 shows high accuracy for detecting Alzheimer's disease in diverse racial groups, with no differences found.
  • In a validation test set, p-tau217/Aβ42 achieved accuracy rates of 0.88 for Black participants and 0.91 for White participants.
  • Receiver-operating characteristic analysis identified critical cut points for amyloid PET positivity in a clinically diverse sample.
  • Findings indicate false negatives are more common in cognitively normal individuals, highlighting potential diagnosis challenges.

Abstract

In clinically and racially diverse training and test sets, we evaluated and validated Alzheimer's disease (AD) plasma biomarkers: phosphorylated tau-217 (p-tau217), amyloid beta 1-42/1-40 (Aβ42/Aβ40), and p-tau217/Aβ42. Inclusion criteria were available plasma, race (people who self-identified as Black/African American pBlack or White pWhite), cognitive status (normal, mild cognitive impairment MCI, dementia), and 18F-florbetaben or 18F-florbetapir positron emission tomography (PET) data. In the training set (n = 289; 28% pBlack), we used receiver-operating characteristic (ROC) analysis to calculate two cut points (0.95 sensitivity and specificity) to detect amyloid PET positivity. Cut points were validated in an independent test set (n = 846; 12% pBlack). In the test set, plasma p-tau217/Aβ42 had the highest accuracy (pBlack: 0.88, pWhite: 0.91) and lowest proportion of intermediate classifications (≤0.16), with no classification difference by race (odds ratio OR = 1.45, 95% confidence interval CI = 0.66-2.95, p = 0.33). False negatives were more likely to be cognitively normal (vs mild cognitive impairment MCI; OR = 7.79, 95% CI = 2.33-40.81, p = 5.1e-05) than correct classifications. Plasma p-tau217/Aβ42 had high accuracy to detect AD, with comparable performance across race. We tested plasma phosphorylated tau-217 (p-tau217)/amyloid beta (Aβ)42, p-tau217, and Aβ42/Aβ40 in diverse training and test sets. In models, race × amyloid PET interactions were not significant. Plasma p-tau217/Aβ42 had the highest accuracy in people who self-identified as Black/African American (pBlack; 0.88) and people who self-identified as White (pWhite; 0.91). Plasma p-tau217/Aβ42 had the lowest proportion of intermediate cases (range = 0.09-0.16). False negatives were more likely to have normal cognition, female sex, and high body mass index.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Cousins et al. (2025) studied this question.

synapsesocial.com/papers/68a3635e0a429f797332a6d8https://doi.org/10.1002/alz.70469
Ask AI
Helpful
Bookmark
Share
View Full Paper