This study reveals how variations in magnetic gap impact hydraulic performance in canned motor pumps, suggesting optimal designs.
The integration of axial flux motors into canned motor pumps offers a promising approach to overcome the efficiency and size limitations of traditional designs, particularly in critical sectors like aerospace. However, the hydrodynamics in magnetic gap between the stator and rotor are poorly understood. This study investigates the effect of magnetic gap on performance and internal flow. Six magnetic gap schemes are developed, ranging from 0.2 to 1.2 mm. Numerical simulations are conducted, and simulation results showed good agreement with experimental data. The magnetic gap exhibits a non-linear effect on performance. The peak head coefficient occurs at a 0.4 mm gap and maximum efficiency at 1.0 mm. At a 0.2 mm gap, strong viscous shear forces increase disk friction loss and create high-vorticity flow. As the gap widens, flow transitions from viscosity-dominated to inertia-dominated, leading to a more ordered flow structure. The blade passing frequency is the dominant frequency. For a gap of 0.8 mm, the pressure fluctuation intensity is lowest. By analyzing performance, head coefficient, velocity, vorticity, entropy production, and pressure fluctuations, a gap of 0.8 mm is identified as the optimal design. This study provides critical guidance for optimizing the design of axial flux canned motor pumps.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: