Research shows moderate inter-reader agreement on TI-RADS in thyroid nodules, suggesting SPECT/CT may enhance evaluation for complex cases.
Aim/introduction In central Europe, up to 76% of population exhibit thyroid nodules (TN). The combination of ultrasound findings and thyroid scan imaging are supposed to ensure a cost-effective and reliable prediction of malignancy risk. However, real-world impact of ultrasound findings, i.e. TI-RADS, has raised concerns due to its highly limited reliability and reproducibility. The recent advancements and increasing access of SPECT/CT scanners might contribute to thyroid management. This study aimed to elucidate additive value of SPECT(-CT) imaging in initial evaluation of complex TN cases, particularly on multinodular goiter and difficult-to-characterize solitary nodules. Materials and methods A total of 61 patients (19 males and 42 females with a mean age of 56 (± 17)) with incidental TN were retrospectively enrolled in this study between November 2022 and July 2023, who underwent both conventional planar thyroid scan and SPECT(-CT) imaging. Three readers with varying experience level selected a target nodule within thyroid gland and evaluated its functionality, ACR TI-RADS categorization and additive benefit of SPECT(-/CT) imaging. Kappa-value for inter-reader agreement (IRA) was interpreted as follows: < 0.01–0.20, slight agreement; 0.21–0.40, fair agreement; 0.41–0.60, moderate agreement; 0.61–0.80, substantial agreement; and 0.81–1.00; almost perfect agreement. Results Of the target TNs, 33 (54%) were located in the left thyroid lobe, 5 (8%) in the isthmus and the remaining target TNs (38%) in the right lobe. The median target TN size was 20 mm (10–59). The target nodule match rate among readers was almost perfect (k-value 0.81; 95% CI: 0.72–0.90). The IRA regarding ACR TI-RADS was moderate with k-value of 0.47 (95% CI: 0.40–0.54). The IRA regarding patient referral was substantial among readers with k-value of 0.60, while k-value was even higher at pairwise comparison of experienced readers (k-value: 0.64). IRA regarding the target TN functionality among readers was good with k-value of 0.68 (95%CI: 0.59–0.77). IRA involving the less experienced reader revealed only slightly lower reliability scores, i.e. a k-value of 0.61. The correlation with ground truth results revealed comparable results among experienced and less-experienced readers. Conclusion Increasing clinical experience of physicians appeared to have a direct correlation with a higher referral rate of SPECT(-CT) imaging, although the additive clinical benefit was only evident for a minority of patients. Hence, SPECT(-CT) imaging might be more suitable for tertiary care centers, as its additive benefit at primary care level would have only negligible effect for patients.
No takes yet. Share an insight, caveat, or question.
Novruzov et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: