Verification of transport and resonance methods in OpenMOC shows improved accuracy and efficiency in reactor physics applications.
The one-step method in reactor physics has become one of the important research directions in recent two decades. Based on the open-source OpenMOC code, the following work was carried out. Firstly, the global–local resonance method with multi-group and continuous neutron libraries was researched and established. Next, based on the 2D and 3D MOC solver, the 2D/1D and the MOC/DD transport methods were realized in OpenMOC. Finally, verification of the transport and resonance methods was conducted using the C5G7 macro benchmark and the VERA micro benchmark. The numerical results demonstrated that the average eigenvalue deviation was 44 pcm and average maximum pin power distribution deviation was 0.37% in the VERA-2 benchmark, which showed the good accuracy of the resonance method. As for the transport method, the 3DMOC method exhibited better accuracy in strong anisotropic cases, but the computational time was 38 times that of the 2D/1D method.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: